Harmonised or product standard

    EN 998-2 - Specification for mortar for masonry - masonry mortar

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 998-2 - Specification for mortar for masonry - masonry mortar. For masonry mortars, Amstelfy covers compressive strength, bond strength, chloride content in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 998-2 is the harmonised specification for factory-made mortars used for laying, jointing and pointing masonry units. It distinguishes designed mortars, where the manufacturer selects the composition to achieve declared performance, from prescribed mortars, made to a stated recipe, and classifies by properties into general purpose G, thin layer T and lightweight L mortars. Declared characteristics include compressive strength class M1 to M20 or Md, bond strength as initial shear strength, chloride content, water absorption, water vapour permeability, thermal conductivity, dry bulk density, durability according to the provisions in the place of use, workable life and reaction to fire. Conformity rests on type testing and factory production control, with the AVCP system depending on whether the mortar is designed or prescribed.

    Type testing and factory production control

    Type testing follows the EN 1015 series: consistence and air content of the fresh mortar, workable life and correction time to EN 1015-9, dry bulk density to EN 1015-10, flexural and compressive strength on prisms to EN 1015-11, chloride content to EN 1015-17 and water absorption to EN 1015-18. Bond strength is declared either from a test to EN 1052-3 with specified units or by the tabulated values the standard permits for each mortar type. Water vapour permeability and thermal conductivity are usually taken from EN 1745 tables. FPC covers constituent control, batching accuracy, strength testing frequency and the records a certification body or Notified Body reviews.

    What the report states

    The type-test report gives the strength class, the initial shear strength in N/mm², chloride content as a percentage of dry mortar, absorption coefficient, density, thermal conductivity and fire class, together with the mortar type and concept. For designed mortars these values appear in the Declaration of Performance; a voluntary product certificate confirms their constancy in production.

    Where the result is required

    CE marking of bagged, silo and ready-to-use masonry mortars across the EEA, structural masonry design to EN 1996-1-1, which takes the mortar class into the unit–mortar combination strength, procurement of thin layer mortars for calcium silicate and aerated concrete units, and the mortar data needed alongside EN 771 units and EN 845 bed joint reinforcement in masonry assessments.

    What we assess

    • compressive strength, bond strength, chloride content

    Products covered

    • masonry mortars

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    A designed mortar is specified by performance, chiefly its M class, and the manufacturer is free in composition; it falls under AVCP system 2+ because strength is used in structural design. A prescribed mortar is defined by proportions, is declared under system 4 and its strength is assumed from the recipe.

    Either by testing initial shear strength to EN 1052-3 on couplets of defined units, or by using the tabulated values the standard allows, 0.15 N/mm² for general purpose and lightweight mortars and 0.30 N/mm² for thin layer mortars. Tested values are needed where the designer relies on higher bond.

    Chlorides accelerate corrosion of bed joint reinforcement, wall ties and embedded steel. EN 998-2 limits the chloride content of the dry mortar to 0.1 % by mass and the manufacturer declares the measured value, which matters where reinforced masonry or stainless-free ties are used.

    Related standards