US qualification standard

    ASTM C666 - Standard test method for resistance of concrete to rapid freezing and thawing

    Testing · NAC-037-TL

    In short

    ASTM C666 - Standard test method for resistance of concrete to rapid freezing and thawing. Amstelfy's laboratory in Amstelveen performs this ASTM method for concrete: freeze-thaw durability factor. Testing is on the ISO/IEC 17025 accreditation scope NAC-037-TL, which lets European manufacturers prepare US evaluation-report programmes without shipping samples overseas.

    What ASTM C666 determines

    ASTM C666/C666M measures the resistance of concrete to rapidly repeated freezing and thawing. Prismatic or cylindrical specimens are cycled between 4 °C and −18 °C, and the internal damage is followed by measuring the fundamental transverse frequency under ASTM C215, from which the relative dynamic modulus of elasticity is calculated. Procedure A freezes and thaws the specimens surrounded by water; Procedure B freezes them in air and thaws them in water, a milder exposure. Testing continues to 300 cycles or until the relative dynamic modulus falls to 60 % of its initial value, whichever comes first. The durability factor condenses the outcome into one number used to compare mixes, air-void systems and aggregates.

    Specimens, conditioning and procedure

    Specimens are moulded or sawn with cross-sections of 75 to 125 mm and lengths of 275 to 405 mm, moist-cured for 14 days unless otherwise specified, and brought to the thaw temperature before the first cycle. Each cycle lowers the specimen temperature from 4 °C to −18 °C and raises it back in not less than 2 h nor more than 5 h, with the thawing portion occupying at least 25 % of the cycle in Procedure A and 20 % in Procedure B. At intervals not exceeding 36 cycles the specimens are removed in the thawed state, weighed, measured for length if required and tested for transverse frequency, then returned in a rotated position.

    What the report states

    The report gives the relative dynamic modulus against cycle number, the durability factor DF = P·N/M, mass change and, where measured, length change for each specimen, with the procedure used and the number of cycles completed. A durability factor near 100 indicates little internal damage; a test stopped early at 60 % relative modulus gives a correspondingly low factor.

    Where the result is required

    Qualification of air-entrained concrete mixes, aggregates suspected of D-cracking, overlay and repair materials and fibre-reinforced concrete for US specifications that set a minimum durability factor, and ICC-ES acceptance criteria that require freeze–thaw resistance of a concrete or grout product. European producers of admixtures and repair mortars use it to add a US-format durability record alongside their EN 13687-1 or CEN/TS 12390-9 data.

    What we assess

    • freeze-thaw durability factor

    Products covered

    • concrete

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    US and international evaluation-report programmes (ICC-ES, IAPMO UES, ACI 318 qualification) accept data from ISO/IEC 17025-accredited laboratories. Amstelfy runs these programmes in the Netherlands so European manufacturers avoid shipping samples overseas; the evaluation report itself is issued by the evaluation service.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Procedure A, freezing and thawing in water, is more severe and is the usual default in US specifications. Procedure B, freezing in air and thawing in water, is chosen where the specification names it or where the service exposure is less saturated. Results from the two procedures are not interchangeable.

    Either 300 cycles or a relative dynamic modulus of 60 % of the initial value, whichever occurs first. If length change is measured, a specification may also set an expansion limit as a stopping point. The durability factor is calculated from the cycle count at termination.

    C666 measures internal damage from freezing of pore water through loss of dynamic modulus, with no salt. Scaling tests such as ASTM C672 or EN 13687-1 expose a surface to a de-icing solution and assess surface loss or bond. A mix can pass one and fail the other.

    Related standards

    All Concrete, fibres, mortars & concrete repair products testing