US qualification standard
ASTM C39 – Concrete cylinder compressive strength test
Standard test method for compressive strength of cylindrical concrete specimens
In short
ASTM C39 - Standard test method for compressive strength of cylindrical concrete specimens. Amstelfy's laboratory in Amstelveen performs this ASTM method for concrete cylinders: compressive strength. Testing is on the ISO/IEC 17025 accreditation scope NAC-037-TL, which lets European manufacturers prepare US evaluation-report programmes without shipping samples overseas.
What ASTM C39 determines
ASTM C39/C39M determines the compressive strength of cylindrical concrete specimens, either cylinders moulded on site or in the laboratory or cores drilled from a structure. The cylinder is loaded axially between a fixed and a spherically seated platen at a stress rate of 0.25 ± 0.05 MPa/s until failure, and the strength is the maximum load divided by the cross-sectional area calculated from the measured diameter. The method is the strength basis of US concrete practice: ACI 318 acceptance of the specified strength f'c, mix qualification under ASTM C94 and the characterisation of test members in anchor and reinforcement qualification programmes all rely on it. The result depends strongly on end preparation, moisture state and age, so the method fixes these.
Specimens, conditioning and procedure
Standard specimens are 150 × 300 mm or 100 × 200 mm cylinders made under ASTM C31 or C192, kept moist until testing and tested within the age tolerances of the method, for example 28 days ± 20 h. Ends must be plane: sulfur-mortar caps, ground ends or unbonded neoprene pads in retaining rings are the options, and the client specifies which. Two diameters at right angles are averaged. Cores with a length-to-diameter ratio below 1.75 receive the correction factors listed in the method. The fracture pattern is compared with the six reference types and recorded.
What the report states
The report gives the individual strength of each cylinder to the nearest 0.1 MPa, the specimen dimensions, age, end preparation, moisture condition and fracture type, together with the average of the set. ACI 318 defines a strength test as the average of two 150 mm or three 100 mm cylinders, so sets are normally cast in these multiples.
Where the result is required
Acceptance testing of ready-mixed concrete under ASTM C94 and ACI 318, strength verification for precast and prestressed elements, and the concrete strength records that ICC-ES acceptance criteria such as AC193 and AC308 and the ACI 355 qualification standards require for every anchor test slab. European manufacturers preparing US evaluation reports use it to document test-member concrete in the same units and format the reviewing body expects.
- EN 12390-3 – European counterpart on cubes and cylinders
- ASTM C94 – ready-mixed concrete acceptance based on C39 results
- ICC-ES AC193 – anchor test slabs characterised with C39 cylinders
- ICC-ES AC308 – adhesive anchor programmes needing cylinder strengths
- ASTM C78 – flexural strength of the same concrete
What we assess
- compressive strength
Products covered
- concrete cylinders
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | No |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
US and international evaluation-report programmes (ICC-ES, IAPMO UES, ACI 318 qualification) accept data from ISO/IEC 17025-accredited laboratories. Amstelfy runs these programmes in the Netherlands so European manufacturers avoid shipping samples overseas; the evaluation report itself is issued by the evaluation service.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- ASTM C78 - Standard test method for flexural strength of concrete (third-point loading)
- ASTM C143/C143M - Standard test method for slump of hydraulic-cement concrete
- ASTM C234 - Standard test method for comparing concretes on the basis of the bond developed with reinforcing steel
- ASTM C666 - Standard test method for resistance of concrete to rapid freezing and thawing
- ASTM C1579 - Standard test method for evaluating plastic shrinkage cracking of restrained fiber reinforced concrete
- ASTM C1581/C1581M - Standard test method for determining age at cracking and induced tensile stress characteristics of mortar and concrete under restrained shrinkage
- ASTM C1609 - Standard test method for flexural performance of fiber-reinforced concrete (beam with third-point loading)
- ASTM D7508 - Standard specification for polyolefin chopped strands for use in concrete