US qualification standard

    ASTM C39 – Concrete cylinder compressive strength test

    Standard test method for compressive strength of cylindrical concrete specimens

    Testing · NAC-037-TL

    In short

    ASTM C39 - Standard test method for compressive strength of cylindrical concrete specimens. Amstelfy's laboratory in Amstelveen performs this ASTM method for concrete cylinders: compressive strength. Testing is on the ISO/IEC 17025 accreditation scope NAC-037-TL, which lets European manufacturers prepare US evaluation-report programmes without shipping samples overseas.

    What ASTM C39 determines

    ASTM C39/C39M determines the compressive strength of cylindrical concrete specimens, either cylinders moulded on site or in the laboratory or cores drilled from a structure. The cylinder is loaded axially between a fixed and a spherically seated platen at a stress rate of 0.25 ± 0.05 MPa/s until failure, and the strength is the maximum load divided by the cross-sectional area calculated from the measured diameter. The method is the strength basis of US concrete practice: ACI 318 acceptance of the specified strength f'c, mix qualification under ASTM C94 and the characterisation of test members in anchor and reinforcement qualification programmes all rely on it. The result depends strongly on end preparation, moisture state and age, so the method fixes these.

    Specimens, conditioning and procedure

    Standard specimens are 150 × 300 mm or 100 × 200 mm cylinders made under ASTM C31 or C192, kept moist until testing and tested within the age tolerances of the method, for example 28 days ± 20 h. Ends must be plane: sulfur-mortar caps, ground ends or unbonded neoprene pads in retaining rings are the options, and the client specifies which. Two diameters at right angles are averaged. Cores with a length-to-diameter ratio below 1.75 receive the correction factors listed in the method. The fracture pattern is compared with the six reference types and recorded.

    What the report states

    The report gives the individual strength of each cylinder to the nearest 0.1 MPa, the specimen dimensions, age, end preparation, moisture condition and fracture type, together with the average of the set. ACI 318 defines a strength test as the average of two 150 mm or three 100 mm cylinders, so sets are normally cast in these multiples.

    Where the result is required

    Acceptance testing of ready-mixed concrete under ASTM C94 and ACI 318, strength verification for precast and prestressed elements, and the concrete strength records that ICC-ES acceptance criteria such as AC193 and AC308 and the ACI 355 qualification standards require for every anchor test slab. European manufacturers preparing US evaluation reports use it to document test-member concrete in the same units and format the reviewing body expects.

    What we assess

    • compressive strength

    Products covered

    • concrete cylinders

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    US and international evaluation-report programmes (ICC-ES, IAPMO UES, ACI 318 qualification) accept data from ISO/IEC 17025-accredited laboratories. Amstelfy runs these programmes in the Netherlands so European manufacturers avoid shipping samples overseas; the evaluation report itself is issued by the evaluation service.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    They are not interchangeable. A 150 mm cube of the same concrete gives a higher value than a 150 × 300 mm cylinder, and the ratio varies with strength level, so each specification must be met with its own specimen shape. The loading rates also differ between the two methods.

    Sulfur caps, ground ends and unbonded neoprene pads are all permitted, within the strength limits each carries in the referenced practices. Pads are quickest for routine work; grinding is preferred for high-strength concrete and for cores. State the choice in the test request so results are comparable across laboratories.

    Yes. Cores are obtained and conditioned under ASTM C42, then tested under C39 with a length-to-diameter correction when the ratio is below 1.75. The report records diameter, length, moisture condition and the correction applied, which an evaluation body or engineer of record can trace.

    Related standards

    All Concrete, fibres, mortars & concrete repair products testing