Harmonised or product standard
EN 771-6 - Specification for masonry units - natural stone masonry units
In short
EN 771-6 - Specification for masonry units - natural stone masonry units. For natural stone products, Amstelfy covers certification of conformity (AVCP) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.
What the standard covers
EN 771-6 is the harmonised specification for natural stone masonry units: blocks and dressed stones that are laid in mortar to form load-bearing or non-load-bearing walls, piers and arches, unlike the cladding slabs, tiles and paving of the other natural stone standards. It defines the characteristics the manufacturer declares: dimensions and tolerances, configuration, compressive strength with the unit category, flexural strength where relevant, apparent density and open porosity, water absorption, freeze-thaw resistance, thermal conductivity, bond strength, reaction to fire, water vapour permeability and the petrographic denomination that identifies the stone. Units are declared as Category I, where the declared compressive strength is met with the confidence level set out in the standard, or Category II otherwise, and the category sets the AVCP system: 2+ with notified body certification of factory production control for Category I, 4 for Category II.
Type testing and factory production control
Type testing samples units from production: dimensions and flatness, compressive strength by the method cited, flexural strength to EN 12372, apparent density and open porosity to EN 1936, water absorption to EN 13755, freeze-thaw resistance to EN 12371 and petrographic examination to EN 12407 with the denomination to EN 12440. Thermal conductivity and water vapour properties are taken from tabulated values or tested, and reaction to fire is class A1 without testing where the organic content is below the limit in the Commission decision. Factory production control covers quarry block selection, sawing and dressing tolerances, periodic strength and absorption tests at the frequencies in the standard, marking and traceability. Certification audits the FPC and samples units for verification.
What the report states
The reports give the measured dimensions against the declared tolerance class, compressive strength in N/mm² as mean and, for Category I, the statistical basis of the declared value, density in kg/m³, open porosity and water absorption in percent, the freeze-thaw result as strength or mass change after cycling, and the petrographic name. The manufacturer declares these in the Declaration of Performance; designers use the compressive strength and category in Eurocode 6 masonry strength calculations.
Where the result is required
EN 771-6 is required for CE marking of natural stone units sold for masonry in the EU and EEA, from rubble and squared stone for load-bearing walls to ashlar for facades, retaining walls, bridge parapets and the restoration of historic structures. It sits alongside the other EN 771 parts for clay, calcium silicate, concrete, aerated concrete and manufactured stone units, and the declared values feed Eurocode 6 design and the choice of masonry mortar under EN 998-2. The other natural stone standards cover cladding, tiles and paving.
What we assess
- certification of conformity (AVCP)
Products covered
- natural stone products
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | No |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | Yes |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EN 845-1 - Ancillary components for masonry - ties, tension straps, hangers and brackets
- EN 845-5 - Ancillary components for masonry - lintels
- EN 845-7 - Ancillary components for masonry - bed joint reinforcement
- EN 13755 - Natural stone test methods - water absorption at atmospheric pressure
- EN 1925 - Natural stone test methods - water absorption coefficient by capillarity
- EN 1341 - Slabs of natural stone for external paving
- EN 1469 - Natural stone products - slabs for cladding
- EN 12057 - Natural stone products - modular tiles