US qualification standard

    ASTM C78 - Standard test method for flexural strength of concrete (third-point loading)

    Testing · NAC-037-TL

    In short

    ASTM C78 - Standard test method for flexural strength of concrete (third-point loading). Amstelfy's laboratory in Amstelveen performs this ASTM method for concrete beams: flexural strength. Testing is on the ISO/IEC 17025 accreditation scope NAC-037-TL, which lets European manufacturers prepare US evaluation-report programmes without shipping samples overseas.

    What ASTM C78 determines

    ASTM C78/C78M measures the flexural strength of plain concrete as the modulus of rupture of a simply supported beam loaded at its third points. Because the whole middle third of the span is under constant maximum moment, the weakest section in that region governs and the method gives a lower, less scattered value than centre-point loading to ASTM C293. The modulus of rupture is calculated from the maximum load, span and section dimensions, and the position of the fracture plane decides which formula applies. It is a strength index for unreinforced concrete in bending, used mainly for pavements and slabs on grade where flexural rather than compressive capacity controls the design.

    Specimens, conditioning and procedure

    Beams are moulded under ASTM C31 or C192 or sawn from hardened concrete, with a span of three times the depth; the common size is 150 × 150 × 500 mm on a 450 mm span. Specimens are kept moist until testing because surface drying lowers the result. The beam is turned on its side relative to casting, seated on the supports, and loaded through two rollers so that the stress on the tension face rises at 0.9 to 1.2 MPa/min until rupture. The fracture location is measured; a break outside the middle third by more than five percent of the span invalidates the test.

    What the report states

    The report states the modulus of rupture to the nearest 0.05 MPa for each beam, the average width and depth at the fracture, the span, the fracture position and the formula used. Sets of beams are reported with their mean. The value is a flexural strength for design and quality control, not a residual or post-cracking property.

    Where the result is required

    Flexural strength specifications for concrete pavements, airfield slabs and industrial floors, mix qualification where a modulus of rupture is specified instead of f'c, and the first-crack reference in fibre-reinforced concrete programmes. ASTM C1116 and project specifications based on ACI 330 or ACI 360 cite it; it also provides the plain-concrete baseline when comparing with ASTM C1609 beams of the same geometry.

    What we assess

    • flexural strength

    Products covered

    • concrete beams

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    US and international evaluation-report programmes (ICC-ES, IAPMO UES, ACI 318 qualification) accept data from ISO/IEC 17025-accredited laboratories. Amstelfy runs these programmes in the Netherlands so European manufacturers avoid shipping samples overseas; the evaluation report itself is issued by the evaluation service.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    C78 loads the beam at two points one third of the span apart, so the maximum moment is constant over the middle third. C293 applies one central load, so only one section sees the peak moment. C293 values are therefore higher and the two cannot be substituted for each other.

    Only for the first-crack or peak strength. Once the matrix cracks, C78 does not control deflection and the post-crack behaviour of fibres is not captured. ASTM C1609 uses the same beam and support geometry with closed-loop deflection control to report residual strengths and toughness.

    The method reports individual beams, so the number follows the specification that calls for the test. Many project and mix-qualification specifications require sets of two or three beams per age, and companion cylinders for ASTM C39 are usually cast from the same batch.

    Related standards

    All Concrete, fibres, mortars & concrete repair products testing