European Assessment Document

    EAD 330076-00-0604 - Metal injection anchors for use in masonry

    Testing · NAC-037-TLCertification · NAC-026-PPSETA route

    In short

    EAD 330076-00-0604 is the EOTA European Assessment Document for metal injection anchors for use in masonry. Amstelfy Technical Solutions tests injection anchors in solid and hollow masonry units against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): characteristic resistance per masonry unit and use category, installation and functioning tests and durability. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.

    What the EAD assesses

    EAD 330076-00-0604 assesses metal injection anchors for masonry: a threaded rod or internally threaded sleeve bonded with injection mortar, in hollow or perforated units usually through a perforated mesh sleeve that contains the mortar. Masonry is not a uniform base material, so the characteristic resistance is not a single number: it is determined for each masonry unit (material, format, compressive strength, hole pattern) in which the anchor is tested, and the ETA lists the units covered. Use categories distinguish dry and wet masonry at installation and in service and the admissible drilling methods, with rotary drilling normally mandatory in hollow units. The EAD also assesses installation safety, behaviour under repeated and sustained load, the spacing and edge distances governed by unit and joint pattern, and durability of metal part and mortar.

    Assessment programme

    Test walls are built from the units to be claimed with the mortar joints specified by the EAD, and anchors are installed in the unit face and, where claimed, near joints, using the manufacturer's sleeves, drilling method and cleaning procedure. Reference tension tests are run in each unit type; shear tests follow where shear resistance is claimed. Functioning series cover reduced hole cleaning, installation in wet units, the maximum installation torque, repeated loads and sustained load. Durability covers freeze-thaw where wet use is claimed, alkaline resistance of the mortar and corrosion protection of the metal part. Recorded failure modes are steel failure, pull-out of the anchor, pull-out of the whole brick and local brick breakout or splitting.

    What the report states

    The report lists, per unit and series, the ultimate loads, displacements, failure modes and 5 % fractile, together with the reduction factors from the functioning tests. The TAB publishes in the ETA a characteristic resistance for each masonry unit and use category, the minimum unit dimensions and strength, spacing and edge distances, installation parameters and the job-site test procedure for units outside the table.

    Where the result is required

    Design uses EOTA TR 054 together with the ETA values, and the anchor is CE marked under the AVCP system given in the EAD. Applications include fixing balconies, canopies, railings, facade brackets and heavy services to brick, calcium-silicate and concrete-block walls, in new build and refurbishment. Versions 00 and 01 of the EAD share this structure; the accreditation lists version 00. Plastic anchors for ETICS in the same walls fall under EAD 330196 instead.

    What we assess

    • characteristic resistance per masonry unit and use category
    • installation and functioning tests
    • durability

    Products covered

    • injection anchors in solid and hollow masonry units

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    No. ETAs are issued by Technical Assessment Bodies designated under the CPR. Amstelfy carries out the assessment tests in its accredited laboratory, prepares the test reports to the EAD's clause structure and coordinates the test plan with the TAB of your choice.

    Because the capacity is set by the unit: web thickness, hole pattern, material strength and whether the mortar can key into the perforations. A resistance measured in one hollow clay block does not transfer to another format. The ETA therefore names each unit tested, and for other units the job-site test procedure in the ETA is used to derive a site-specific value.

    Send full pallets of each unit you want listed, from regular production, with the declared compressive strength and unit drawings; dimensions and strength are verified before the walls are built. Choose units representative of your main markets, since each additional unit type adds a complete reference series and part of the functioning tests.

    Only if that position was tested. The EAD allows the ETA to cover installation in the unit, in the joint or at a defined distance from it, each with its own tests, because joints are weaker and more variable than the unit. Most ETAs restrict installation to the unit face and set a minimum distance to the joints.