Harmonised or product standard

    EN 998-1 - Specification for mortar for masonry - rendering and plastering mortar

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 998-1 - Specification for mortar for masonry - rendering and plastering mortar. For rendering and plastering mortars, Amstelfy covers compressive strength, adhesion, water absorption, vapour permeability in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 998-1 is the harmonised specification for factory-made rendering and plastering mortars for external and internal use on walls, ceilings, columns and partitions. It defines mortar types by purpose, general purpose GP, lightweight LW, coloured CR, one-coat for external use OC, renovation R and thermal insulating T, and sets the characteristics the manufacturer declares: compressive strength category CS I to CS IV, capillary water absorption category W0, W1 or W2, adhesion with its fracture pattern, water vapour permeability, thermal conductivity, durability against freeze–thaw according to the provisions where the mortar is used, and reaction to fire. Conformity is shown by initial type testing and factory production control; the mortar then carries a Declaration of Performance and CE marking under the AVCP system in Annex ZA.

    Type testing and factory production control

    A type-testing programme uses the EN 1015 series: consistence and bulk density of the fresh mortar, dry bulk density, flexural and compressive strength on 40 × 40 × 160 mm prisms to EN 1015-11, adhesion to a defined substrate by pull-off to EN 1015-12, capillary water absorption to EN 1015-18, water vapour permeability to EN 1015-19 and, for OC mortars, water permeability after climatic conditioning to EN 1015-21. Thermal conductivity may be tabulated from EN 1745 or measured. Reaction to fire is classified to EN 13501-1, with class A1 available without testing when the organic content is at or below 1 % by mass. FPC covers raw materials, batching, mixing and finished-product checks at set frequencies.

    What the report states

    The type-test report states the compressive strength category, absorption category, adhesion in MPa with its fracture pattern, μ-value, density, thermal conductivity and fire class, all referenced to the product type. The manufacturer transfers these into the Declaration of Performance; a voluntary product certificate confirms that production continues to meet them.

    Where the result is required

    CE marking of bagged and silo renders, plasters, one-coat renders, renovation plasters for damp masonry and insulating plasters sold in the EEA; procurement specifications for ETICS base coats, repair renders and heritage work; and comparison between suppliers on strength category, absorption and adhesion. It also underpins the render requirements in masonry and ETICS systems assessed under EADs.

    What we assess

    • compressive strength, adhesion, water absorption, vapour permeability

    Products covered

    • rendering and plastering mortars

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    CS I to CS IV are compressive strength categories at 28 days, from 0.4 to 2.5 N/mm² for CS I up to 6 N/mm² and above for CS IV. W0, W1 and W2 are capillary water absorption categories: W0 not specified, W1 at most 0.40 and W2 at most 0.20 kg/m²·min⁰·⁵. Both appear on the CE label.

    One-coat external renders, type OC, must demonstrate water permeability after climatic conditioning on a defined substrate. Thermal insulating mortars, type T, must declare thermal conductivity by measurement and meet class T1 or T2. Renovation mortars, type R, have additional requirements on porosity and absorption.

    Adhesion is measured by pull-off on a substrate defined in EN 1015-12 and declared as a value in N/mm² together with the fracture pattern, coded A, B or C in the standard according to whether failure was adhesive at the interface, cohesive in the mortar or cohesive in the substrate. For OC mortars the standard also requires adhesion after conditioning.