Harmonised or product standard
EN 998-1 - Specification for mortar for masonry - rendering and plastering mortar
In short
EN 998-1 - Specification for mortar for masonry - rendering and plastering mortar. For rendering and plastering mortars, Amstelfy covers compressive strength, adhesion, water absorption, vapour permeability in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.
What the standard covers
EN 998-1 is the harmonised specification for factory-made rendering and plastering mortars for external and internal use on walls, ceilings, columns and partitions. It defines mortar types by purpose, general purpose GP, lightweight LW, coloured CR, one-coat for external use OC, renovation R and thermal insulating T, and sets the characteristics the manufacturer declares: compressive strength category CS I to CS IV, capillary water absorption category W0, W1 or W2, adhesion with its fracture pattern, water vapour permeability, thermal conductivity, durability against freeze–thaw according to the provisions where the mortar is used, and reaction to fire. Conformity is shown by initial type testing and factory production control; the mortar then carries a Declaration of Performance and CE marking under the AVCP system in Annex ZA.
Type testing and factory production control
A type-testing programme uses the EN 1015 series: consistence and bulk density of the fresh mortar, dry bulk density, flexural and compressive strength on 40 × 40 × 160 mm prisms to EN 1015-11, adhesion to a defined substrate by pull-off to EN 1015-12, capillary water absorption to EN 1015-18, water vapour permeability to EN 1015-19 and, for OC mortars, water permeability after climatic conditioning to EN 1015-21. Thermal conductivity may be tabulated from EN 1745 or measured. Reaction to fire is classified to EN 13501-1, with class A1 available without testing when the organic content is at or below 1 % by mass. FPC covers raw materials, batching, mixing and finished-product checks at set frequencies.
What the report states
The type-test report states the compressive strength category, absorption category, adhesion in MPa with its fracture pattern, μ-value, density, thermal conductivity and fire class, all referenced to the product type. The manufacturer transfers these into the Declaration of Performance; a voluntary product certificate confirms that production continues to meet them.
Where the result is required
CE marking of bagged and silo renders, plasters, one-coat renders, renovation plasters for damp masonry and insulating plasters sold in the EEA; procurement specifications for ETICS base coats, repair renders and heritage work; and comparison between suppliers on strength category, absorption and adhesion. It also underpins the render requirements in masonry and ETICS systems assessed under EADs.
What we assess
- compressive strength, adhesion, water absorption, vapour permeability
Products covered
- rendering and plastering mortars
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | Yes |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- ASTM C39 - Standard test method for compressive strength of cylindrical concrete specimens
- ASTM C78 - Standard test method for flexural strength of concrete (third-point loading)
- ASTM C143/C143M - Standard test method for slump of hydraulic-cement concrete
- ASTM C234 - Standard test method for comparing concretes on the basis of the bond developed with reinforcing steel
- ASTM C666 - Standard test method for resistance of concrete to rapid freezing and thawing
- ASTM C1579 - Standard test method for evaluating plastic shrinkage cracking of restrained fiber reinforced concrete
- ASTM C1581/C1581M - Standard test method for determining age at cracking and induced tensile stress characteristics of mortar and concrete under restrained shrinkage
- ASTM C1609 - Standard test method for flexural performance of fiber-reinforced concrete (beam with third-point loading)