Harmonised or product standard

    EN 845-7 - Ancillary components for masonry - bed joint reinforcement

    Testing · NAC-037-TL

    In short

    EN 845-7 - Ancillary components for masonry - bed joint reinforcement. For bed joint reinforcement, Amstelfy covers tensile and weld shear strength and dimensions in its ISO/IEC 17025-accredited laboratory (NAC-037-TL). Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    Bed joint reinforcement is a prefabricated steel mesh, ladder or truss type, laid in the mortar bed of masonry to control cracking or to provide reinforcement in bending and shear. Its specification in the EN 845 series, published by CEN as EN 845-3, defines what is declared: the type and geometry (width, wire diameters, cross-wire spacing, length), the steel grade with its tensile strength, yield and elongation, the shear load capacity of the welded joints, the bond strength with mortar, and the material and coating reference that governs durability, from plain or galvanised carbon steel to austenitic stainless steel. Type testing uses the EN 846 methods and the steel standards for wire; factory production control keeps weld quality and wire properties under control.

    Type testing and factory production control

    Longitudinal wires are tensile tested on a universal machine to the steel standard cited, giving tensile strength, yield or proof stress and elongation. Weld shear capacity is measured to EN 846-3: the cross wire is held while the longitudinal wire is pulled until the weld shears, and the force is compared with the force at the specified yield strength of the longitudinal wire. Bond strength to EN 846-2 is measured by pulling reinforcement out of masonry prisms built with the declared mortar. Dimensions, wire diameters, spacing and coating are checked on production pieces. A type-testing programme covers each wire diameter, width and material reference; FPC includes wire certificates, routine weld shear checks and dimensional control.

    What the report states

    The report gives wire tensile results in N/mm² with elongation, weld shear forces for each joint tested with the percentage of the longitudinal wire's yield force achieved, bond strength from the pull-out series with the failure mode, and measured dimensions against the declared tolerances. Coating thickness or mass, or the stainless grade, is recorded. The manufacturer uses these to declare the characteristic values in the Declaration of Performance.

    Where the result is required

    The specification is cited for CE marking of bed joint reinforcement sold in the EU and EEA and by designers of reinforced masonry to Eurocode 6, where the declared steel properties and bond enter the design. Applications are crack control above and below openings, long walls without movement joints, the lintel zones of composite lintels, confined masonry and the strengthening of existing walls. Galvanised and stainless types are selected by exposure class using the material reference.

    What we assess

    • tensile and weld shear strength
    • dimensions

    Products covered

    • bed joint reinforcement

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Ladder type has two parallel longitudinal wires joined by straight cross wires welded at right angles; truss type uses a continuous zig-zag diagonal wire. Both are covered by the same specification, but the weld geometry differs, so weld shear tests and dimensional checks are run separately for each type and each wire diameter the manufacturer declares.

    The cross wires provide anchorage and keep the longitudinal wires at the correct spacing in the joint. If the welds fail at low load the reinforcement behaves like loose wires with poor bond. The standard therefore requires the weld to resist a defined fraction of the longitudinal wire's yield force, which EN 846-3 measures directly.

    Typically several full-length pieces per width and wire diameter, so that tensile specimens, a series of welded joints and the lengths embedded in bond prisms can all be cut from production material. The laboratory also needs the mortar designation and, for bond tests, the masonry units the manufacturer intends to declare.

    Related standards