Test method
ISO 11925-2 - Reaction to fire tests - ignitability of products subjected to direct impingement of flame - single-flame source test
In short
ISO 11925-2 - Reaction to fire tests - ignitability of products subjected to direct impingement of flame - single-flame source test. Amstelfy's laboratory determines ignitability with single flame source of construction products (Euroclass E / small flame) according to ISO 11925-2 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.
What ISO 11925-2 determines
ISO 11925-2, adopted in Europe as EN ISO 11925-2, tests how readily a construction product ignites when a small flame touches it, representing a match or a burning droplet. A vertical specimen 250 mm high and 90 mm wide is exposed to a 20 mm propane flame from a burner tilted at 45 degrees, applied to the bottom edge or to the surface, and the observer records whether ignition occurs, whether the flame tip reaches a mark 150 mm above the application point within the observation time, and whether burning droplets ignite filter paper beneath the specimen. In the EN 13501-1 classification system the test alone decides class E, with a 15 second flame application, and it is a prerequisite with a 30 second application for classes B, C and D, which also require the SBI test of EN 13823.
Specimens, conditioning and procedure
Specimens are cut from the product in both production directions and conditioned at 23 °C and 50 per cent relative humidity; multilayer products, products with exposed edges and products thicker than the chamber allows are prepared as the standard and EN 13501-1 require. The specimen hangs vertically in the test chamber, the burner is set to the 20 mm flame height and moved into position for surface or edge exposure. Flame is applied for 15 seconds for a class E assessment or 30 seconds for the higher classes, then withdrawn, and observation continues to 20 or 60 seconds respectively. Filter paper under the specimen records flaming droplets. Each exposure and direction is repeated on a set of specimens.
What the report states
The report records, per specimen, whether ignition occurred, the time at which the flame tip reached the 150 mm mark, and the occurrence of flaming droplets and ignition of the filter paper. The results are summarised as flame spread Fs reaching or not reaching 150 mm within the observation time and as droplet behaviour. The test report supports a classification report under EN 13501-1, giving class E, the d0, d1 or d2 droplet designation, or eligibility for SBI testing.
Where the result is required
The small-flame test underpins class E, the most common declared reaction-to-fire class for sealants, adhesives, membranes, plastic sheets, insulation foams and many composite and timber-based products, and it is the first step towards classes B, C and D for insulation, ETICS kits, sandwich panels and claddings. It appears in the type-testing programmes of harmonised standards such as EN 13163, EN 13164 and EN 14509 and of EADs for ETICS and liquid applied roof waterproofing kits. The classification itself is expressed through EN 13501-1.
- EN 15651-1 – facade sealants declaring class E
- EN 13163 – EPS insulation, reaction to fire by small flame
- EN 13164 – XPS insulation, reaction to fire by small flame
- EAD 040083 – ETICS kits with reaction-to-fire assessment
- EN 14509 – sandwich panels with reaction-to-fire class
- EAD 030350 – liquid applied roof waterproofing kits
What we assess
- ignitability with single flame source
Products covered
- construction products (Euroclass E / small flame)
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | No |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.