European Assessment Document

    EAD 040083-01-0404 - External Thermal Insulation Composite Systems (ETICS) with renderings

    Testing · NAC-037-TLCertification · NAC-026-PPSETA route

    In short

    EAD 040083-01-0404 is the EOTA European Assessment Document for external thermal insulation composite systems (etics) with renderings. Amstelfy Technical Solutions tests ETICS kits with EPS, mineral wool, PIR/PUR or other insulation and a rendering system against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): hygrothermal behaviour on the test rig, freeze-thaw behaviour, bond strength of adhesive, base coat and render and impact resistance. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.

    What the EAD assesses

    EAD 040083-01-0404 is the European Assessment Document for external thermal insulation composite systems with a rendering system, the successor of ETAG 004. A kit comprises the factory-made insulation (EPS, mineral wool slabs or lamellas, PIR/PUR, XPS, cork or other), the adhesive and/or mechanical fixings, the base coat with its reinforcing mesh, the key coat and finishing coat, and ancillary profiles. The EAD assesses the system as a whole for the essential characteristics of reaction to fire and continuous smouldering, watertightness, hygrothermal behaviour, freeze-thaw behaviour, impact resistance, water vapour permeability, bond strength between all layers in dry and aged condition, resistance to wind load for the fixing method used, thermal resistance including the point transmittance of anchors, and release of dangerous substances. The fixing method, purely bonded, bonded with supplementary anchors, mechanically fixed with supplementary adhesive or purely mechanical, decides which test families apply. AVCP is system 1 or 2+ depending on the reaction-to-fire class.

    Assessment programme

    Component characterisation comes first: insulation under the harmonised standards, mesh under EAD 040016, anchors under EAD 330196, and the base coat and rendering for capillary water absorption, vapour permeability and bond strength. The system is then applied on a full-scale rig and conditioned under EN 16383 with 80 heat–rain cycles between surface heating to 70 °C and cold-water spraying, then 5 heat–cold cycles down to −20 °C; bond and impact tests follow on the aged surface. Freeze–thaw cycling is added when capillary absorption after 24 h reaches the EAD threshold. Impacts at 3 J and 10 J, and higher energies where claimed, are classified by damage level. Wind-load resistance comes from anchor pull-through tests under EN 16382, the static foam block test and, where claimed, dynamic wind uplift tests.

    What the report states

    The report, organised by EAD clause, gives bond strengths in kPa with the percentage of each rupture type, dry and after hygrothermal, freeze-thaw and water-immersion conditioning, against the minimum values of the EAD tables; the rig observations after cycling; water absorption after 1 h and 24 h; the impact damage level A to D per energy and preconditioning; anchor pull-through resistances as 5 % fractiles; the diffusion-equivalent air layer thickness sd of the rendering; and the thermal data. A Technical Assessment Body uses it to draw up the ETA.

    Where the result is required

    ETICS kits need an ETA under this EAD for CE marking, and the ETA is the basis for national approvals and for installer certification schemes across Europe. The reports also serve kit holders adding a new insulation, render or anchor to an existing ETA, system suppliers who private-label a kit, and manufacturers of components who want their product named in several kits. Voluntary product certification of ETICS kits under ISO/IEC 17065 is also available, distinct from the Notified Body tasks under the AVCP system.

    What we assess

    • hygrothermal behaviour on the test rig
    • freeze-thaw behaviour
    • bond strength of adhesive, base coat and render
    • impact resistance
    • water absorption and water vapour permeability
    • wind load resistance / pull-through of anchors

    Products covered

    • ETICS kits with EPS, mineral wool, PIR/PUR or other insulation and a rendering system

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    No. ETAs are issued by Technical Assessment Bodies designated under the CPR. Amstelfy carries out the assessment tests in its accredited laboratory, prepares the test reports to the EAD's clause structure and coordinates the test plan with the TAB of your choice.

    Every component as sold, in production batches with batch numbers: insulation boards of the thickness range, adhesive and base-coat mortars, mesh rolls, key and finishing coats in the colours or grain sizes to be covered, anchors with plates, and profiles. The rig and the specimens are built by the laboratory from the kit holder's installation instructions, which become part of the assessment.

    The rig cycles are always run. Freeze-thaw conditioning of rendered specimens is added when the mean capillary water absorption of the base coat or of the complete rendering system after 24 h reaches 0.5 kg/m²; systems below that value are deemed freeze-thaw resistant without the extra cycles. The water absorption test is therefore done early in the programme.

    Specimens taken from the conditioned rig receive hard-body impacts of 3 J and 10 J, and higher energies up to those of EN 13497 where the kit holder claims them. The damage observed, from no visible damage to perforation, is recorded as a damage level A to D with the energy and preconditioning noted, which replaces the use categories I to III of ETAG 004.