    EAD 040016-01-0404 is the EOTA European Assessment Document for glass fibre mesh for reinforcement of cementitious or cement-based renderings. Amstelfy Technical Solutions tests alkali-resistant glass fibre reinforcing mesh for ETICS and renders against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): tensile strength and elongation as delivered and after alkali ageing, mesh size and mass per unit area and reaction to fire data support. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.

    What the EAD assesses

    EAD 040016-01-0404 covers glass fibre meshes, rectangular or triaxial, embedded as reinforcement in cementitious or cement-based renderings, with mesh openings between 3 mm and 40 mm and in two variants: standard mesh as primary reinforcement and reinforced mesh as supplementary layer. The mesh must carry the tensile stresses that temperature and moisture movements induce in the render and must keep doing so in the alkaline pore solution of cement over the assumed working life. Durability is therefore the central characteristic: tensile strength and elongation are measured in warp and weft as delivered and after immersion in an alkaline solution, and the retained strength is judged against an absolute minimum and a percentage of the initial value. Supporting characteristics are mesh size and opening, mass per unit area, coating and glass content by loss on ignition, thickness, gross heat of combustion and reaction to fire. AVCP is system 2+, with system 1 for certain reaction-to-fire classes.

    Assessment programme

    Strips 50 mm wide and at least 300 mm long are cut in both directions and tested in tension with a 200 mm free length at 100 mm/min, following EN 13496, at least ten per direction. A second set of ten per direction is immersed for 28 days at 23 °C in a solution of 1 g sodium hydroxide, 4 g potassium hydroxide and 0.5 g calcium hydroxide per litre, rinsed, dried for 48 h and tested in the same way. Mesh size and opening are measured across twenty spacings, mass per unit area on 1 m lengths, and coating content by ignition at 625 °C under ISO 1887. The client states the products, weights and variant to be covered.

    What the report states

    The report gives, for warp and weft separately, the initial and residual breaking force per 50 mm and elongation, the residual strength as a percentage of the initial value, and the comparison with the EAD criteria: at least 1000 N per 50 mm after ageing and at least 50 % retained for standard mesh or 40 % for reinforced mesh. Mesh size, opening and coverage ratio, mass per unit area, coating content and thickness follow with their tolerances. The TAB transfers the values to the ETA tables.

    Where the result is required

    Mesh ETAs under this EAD let a reinforcement producer supply ETICS kit holders and render manufacturers, who cite the mesh in their own ETAs under EAD 040083 or in EN 998-1 render systems without re-testing the component, and they underpin factory production control of weaving and coating lines. The same tensile and alkali-resistance characterisation is asked for by rendered board cladding kits under EAD 090019 and by textile-reinforced mortar systems for strengthening.

    What we assess

    • tensile strength and elongation as delivered and after alkali ageing
    • mesh size and mass per unit area
    • reaction to fire data support

    Products covered

    • alkali-resistant glass fibre reinforcing mesh for ETICS and renders

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    No. ETAs are issued by Technical Assessment Bodies designated under the CPR. Amstelfy carries out the assessment tests in its accredited laboratory, prepares the test reports to the EAD's clause structure and coordinates the test plan with the TAB of your choice.

    Ordinary glass fibres are attacked by the alkaline pore solution of cement and lose strength within months. Alkali-resistant glass and protective coatings slow this attack, and the 28-day immersion in the sodium, potassium and calcium hydroxide solution checks that the protection works: the mesh must keep at least 1000 N per 50 mm and the required proportion of its initial strength, otherwise it cannot be used in a render.

    Yes. Woven meshes usually have different yarn counts and coating uptake in the two directions, so strength and elongation are tested and reported for warp and weft individually, both as delivered and after ageing, with at least ten specimens each. Both directions must meet the criteria, and the ETA lists them separately so that kit holders can check the orientation requirements in their installation instructions.

    Forty tensile strips per product plus pieces for mesh size, mass and ignition tests are cut from full-width roll, so a few metres per product weight suffice for testing. For an ETA the TAB generally asks for material from more than one production lot so that the initial values are representative; the lot numbers are recorded in the report, and meshes with very open structures are tested by the wide-width method instead.

    Related standards

    All ETICS, cladding kits, sandwich panels & building envelope testing