Test method

    EN 1542 - Products and systems for the protection and repair of concrete structures - pull-off test

    Testing · NAC-037-TL

    In short

    EN 1542 - Products and systems for the protection and repair of concrete structures - pull-off test. Amstelfy's laboratory determines pull-off (adhesion) strength of repair mortars, coatings according to EN 1542 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN 1542 determines

    EN 1542 measures the bond between a protection or repair product and a concrete substrate by direct tension. The product is applied to a slab of reference concrete made to EN 1766, cured, and partially cored through the product into the substrate so that a 50 mm diameter test area is isolated. A steel dolly is glued to each core and pulled perpendicular to the surface at a constant stress rate of 0.05 ± 0.01 MPa/s until separation. The failure stress is the pull-off strength, and the location of the fracture, in the substrate, in the product, at an interface, or in the glue, tells the engineer whether the bond or the material governed. Within EN 1504 it is the common adhesion test for coatings, mortars and bonding agents.

    Specimens, conditioning and procedure

    Reference substrates are MC(0,40) concrete slabs cast and conditioned as EN 1766 requires, surface-prepared by grit blasting or as the product data sheet specifies. The product is applied at its intended thickness and cured under the laboratory conditions and times the referencing standard sets. Cores are drilled through the layer and a short distance into the substrate without disturbing the bond, dollies are bonded with a rigid adhesive, and the tensile tester is aligned normal to the surface. At least five positions per slab are pulled, and the fracture face of each is classified into the failure types A, A/B, B, B/C, C, -/Y, Y or Y/Z that the standard defines.

    What the report states

    The report lists the pull-off strength of each position in MPa with the mean, the percentage area of each failure type, the substrate, product thickness, curing and any preconditioning such as thermal cycling. The result is compared with the class limit in the product standard, which usually also sets a lower bound for the smallest single value.

    Where the result is required

    Adhesive bond of repair mortars under EN 1504-3, adhesion of surface protection systems under EN 1504-2, bond after thermal compatibility cycling under EN 13687-1, bonding agents under EN 1504-4, and site quality control of applied works under EN 1504-10. The same test underpins adhesion requirements in rendering and strengthening mortars assessed under EADs for FRCM and CRM systems.

    What we assess

    • pull-off (adhesion) strength

    Products covered

    • repair mortars, coatings

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Type A is cohesive failure in the substrate concrete, which means the bond exceeded the tensile strength of the concrete and the product passed the test in the most favourable way. Type B is cohesive failure in the product. Y-type failures are in the glue or at the dolly and invalidate the position.

    Each condition, for example as-cured and after thermal cycling, needs its own slab with at least five pull-off positions. Product standards may require more. Slabs are cast and conditioned in advance, so the client should state the number of conditions early.

    For product qualification under EN 1504 the reference concrete is mandatory because the class limits assume it. For investigations or site mock-ups the method can be applied to other substrates, in which case the report identifies the substrate and does not compare the result with the EN 1504 classes.

    Related standards