    EN 1504-3 - Products and systems for the protection and repair of concrete structures - part 3: structural and non-structural repair. For concrete repair and protection products, Amstelfy covers structural and non-structural repair in its ISO/IEC 17025-accredited laboratory (NAC-037-TL). Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 1504-3 is the harmonised standard for mortars and concretes used to restore or replace defective concrete and to reinstate the structural section. It defines four classes: R1 and R2 for non-structural repair, R3 and R4 for structural repair, with performance thresholds that rise with class. Characteristics include compressive strength, chloride ion content, adhesive bond to reference concrete, restrained shrinkage and expansion, carbonation resistance, elastic modulus, thermal compatibility, capillary absorption, skid resistance where relevant, coefficient of thermal expansion, reaction to fire and dangerous substances. The standard covers CC, PCC and PC mortars applied by hand, by recasting or by spraying. Conformity is by type testing and factory production control under the AVCP system for structural or non-structural use given in Annex ZA.

    Type testing and factory production control

    Type testing for a structural mortar comprises compressive strength to EN 12190, chloride content to EN 1015-17, adhesive bond by pull-off to EN 1542 on MC(0,40) slabs, restrained shrinkage and expansion to EN 12617-4 judged by bond and cracking, elastic modulus to EN 13412, accelerated carbonation to EN 13295 compared with a reference concrete, thermal compatibility by 50 freeze–thaw cycles with de-icing salt to EN 13687-1 and optionally thunder-shower and dry cycling, capillary absorption to EN 13057 and coefficient of thermal expansion to EN 1770 for PC mortars. Non-structural classes omit modulus and carbonation. Specimens are cast from the bagged product at the stated water or resin ratio.

    What the report states

    The report states each result against the class threshold: compressive strength at least 45 MPa for R4, 25 for R3, 15 for R2 and 10 for R1; bond at least 2.0, 1.5, 0.8 and 0.8 MPa; modulus at least 20 GPa for R4 and 15 GPa for R3; chloride not above 0.05 %; bond after restrained shrinkage and after freeze–thaw at the same class minima; and capillary absorption not above 0.5 kg/m²·h⁰·⁵. The class is then declared.

    Where the result is required

    CE marking of hand-applied, poured and sprayed repair mortars and micro-concretes for principles 3, 4 and 7 of EN 1504-9, specification of R3 and R4 mortars for structural reinstatement on bridges, car parks, marine and industrial structures, and R1 and R2 mortars for cosmetic and levelling work. Test data also support the mortar component of strengthening systems assessed under EADs for FRCM and CRM.

    What we assess

    • structural and non-structural repair

    Products covered

    • concrete repair and protection products

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Both are structural classes. R4 demands higher strength, modulus and bond and is specified where the repair must carry load in a highly stressed member or match a high-strength substrate. R3 suits most structural reinstatement where the original concrete is of moderate class. The designer sets the class from the structure.

    EN 13295 measures carbonation depth after accelerated exposure, and EN 1504-3 requires the mortar to carbonate no deeper than a reference concrete MC(0,45). This ensures a structural repair does not let carbonation reach the reinforcement faster than the surrounding concrete would.

    Enough to cast the prisms, slabs and specimens for every characteristic in the class, including the 50-cycle freeze–thaw slabs and the restrained shrinkage slabs. For a hand-applied mortar this is usually several bags from one production batch, together with the data sheet stating mixing water and layer thickness.

    Related standards