    EN 1348 - Adhesives for tiles - tensile adhesion strength of cementitious adhesives. Amstelfy's laboratory determines tensile adhesion strength (initial, water, heat, freeze-thaw) of adhesives, tile adhesives and tapes according to EN 1348 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN 1348 determines

    EN 1348 measures the tensile adhesion strength of a cementitious tile adhesive, the stress needed to pull a tile perpendicularly off the bed of adhesive. Tiles are fixed to a concrete slab with a defined adhesive thickness and loaded with a pull-head plate glued to the tile face; the failure load divided by the tile area gives the adhesion strength. Because adhesives in service are wetted, heated and frozen, the standard tests the bond not only after standard curing but after water immersion, after heat ageing and after freeze-thaw cycles, each of which attacks a different weakness: hydration, polymer softening and ice pressure at the interface. These four values are the fundamental characteristics for classes C1 and C2 in EN 12004-1, and the method has been carried over into EN 12004-2.

    Specimens, conditioning and procedure

    The adhesive is mixed as the data sheet prescribes and combed onto a conditioned concrete slab with the notched trowel the standard specifies; after the open time the standard sets, ten reference tiles per condition are placed and loaded with a defined weight for a short period. Conditioning follows: 28 days in the standard climate for the initial value; standard climate then immersion in water; standard climate then heat ageing at 70 °C followed by a day of recovery; and standard climate, water storage and 25 freeze-thaw cycles between water at room temperature and a freezer. Pull-head plates are glued to the tiles with an epoxy and the load is applied at 250 N/s until failure.

    What the report states

    The report gives the ten individual values and the mean tensile adhesion strength in N/mm² for each conditioning regime, together with the failure pattern for every tile: adhesive failure at the tile or at the concrete, cohesive failure within the adhesive, within the tile or within the slab. Means are compared with the EN 12004-1 limits of 0.5 N/mm² for class C1 and 1.0 N/mm² for class C2 in all four regimes.

    Where the result is required

    EN 1348 adhesion values are the core of the Declaration of Performance for cementitious adhesives under the harmonised EN 12004 standard, of class C1 and C2 claims, and of voluntary product certification. They are also used for improved adhesives in combination with the open time, slip and deformation tests, in audit testing by certification bodies, and in factory production control where the initial value is checked on production batches. Tile and substrate manufacturers use the method to qualify adhesive combinations.

    What we assess

    • tensile adhesion strength (initial, water, heat, freeze-thaw)

    Products covered

    • adhesives
    • tile adhesives
    • tapes

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Each regime targets a different cause of bond loss in service. The initial value shows the quality of the cured bond; water immersion reveals re-emulsification or weak polymer films; heat ageing exposes drying shrinkage and loss of flexibility; freeze-thaw cycling tests the resistance of the interface to ice pressure. A cementitious adhesive must meet the class limit in all four.

    EN 12004-2 incorporated the EN 1348 procedure when the tile adhesive test methods were consolidated, so the physical test is the same. Reports cite EN 1348 where the harmonised standard cited in the Official Journal or a client's specification refers to it, and EN 12004-2 where the newer requirements standard is being applied. Both numbers can appear on one report.

    The standard prescribes reference tiles of fully vitrified porcelain stoneware with a defined size and low water absorption, and concrete slabs with specified composition, age and surface finish so that results are comparable between laboratories. A client may additionally request tests with its own tiles or substrates, which are then reported as supplementary and not as the classification test.