Harmonised or product standard
EN 1504-2 - Products and systems for the protection and repair of concrete structures - part 2: surface protection systems for concrete
In short
EN 1504-2 - Products and systems for the protection and repair of concrete structures - part 2: surface protection systems for concrete. For concrete repair and protection products, Amstelfy covers surface protection systems for concrete in its ISO/IEC 17025-accredited laboratory (NAC-037-TL). Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.
What the standard covers
EN 1504-2 is the harmonised standard for products that protect the concrete surface: hydrophobic impregnations that line the pores and repel water, impregnations that fill the pores, and coatings that form a continuous film. It links each product to the principles it can serve, protection against ingress, moisture control, physical and chemical resistance and increasing resistivity, and lists the performance characteristics to be declared for each intended use: permeability to water vapour, carbon dioxide and liquid water, capillary absorption, adhesion by pull-off, crack bridging, abrasion and impact resistance, resistance to severe chemical attack, thermal compatibility, depth of penetration for impregnations, drying rate and reaction to fire. Conformity follows type testing plus factory production control; the AVCP system depends on use and fire performance.
Type testing and factory production control
A type-testing programme selects the characteristics for the declared principles and applies the referenced methods: capillary absorption and permeability to water to EN 1062-3, water vapour permeability to EN ISO 7783, carbon dioxide permeability to EN 1062-6, adhesion to EN 1542 on reference concrete, crack bridging ability to EN 1062-7 in static or dynamic classes, impact resistance to EN ISO 6272-1 in three classes, abrasion to EN ISO 5470-1, thermal compatibility to EN 13687-1 or its sibling parts, and chemical resistance by immersion. Hydrophobic impregnations are tested for penetration depth, water absorption and alkali resistance, and drying rate. FPC covers raw materials, batch records and finished-product identity tests.
What the report states
The report gives each measured characteristic against the class or limit in the standard, for example adhesion of at least 1.0 MPa for rigid systems without traffic and 2.0 MPa with traffic, crack bridging class, impact class, permeability values and the thermal compatibility result, together with the product type and intended principles. These become the declared performances in the DoP.
Where the result is required
CE marking of anti-carbonation coatings, car park deck coatings, silane and siloxane treatments for bridges and marine structures, pore-filling sealers and chemically resistant linings; specification of protection in repair projects designed under EN 1504-9 principles 1, 2, 5, 6 and 8; and the test evidence owners ask for when they want third-party confirmation of a declared performance.
What we assess
- surface protection systems for concrete
Products covered
- concrete repair and protection products
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | No |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- ASTM C39 - Standard test method for compressive strength of cylindrical concrete specimens
- ASTM C78 - Standard test method for flexural strength of concrete (third-point loading)
- ASTM C143/C143M - Standard test method for slump of hydraulic-cement concrete
- ASTM C234 - Standard test method for comparing concretes on the basis of the bond developed with reinforcing steel
- ASTM C666 - Standard test method for resistance of concrete to rapid freezing and thawing
- ASTM C1579 - Standard test method for evaluating plastic shrinkage cracking of restrained fiber reinforced concrete
- ASTM C1581/C1581M - Standard test method for determining age at cracking and induced tensile stress characteristics of mortar and concrete under restrained shrinkage
- ASTM C1609 - Standard test method for flexural performance of fiber-reinforced concrete (beam with third-point loading)