Harmonised or product standard

    EN 1504-2 - Products and systems for the protection and repair of concrete structures - part 2: surface protection systems for concrete

    Testing · NAC-037-TL

    In short

    EN 1504-2 - Products and systems for the protection and repair of concrete structures - part 2: surface protection systems for concrete. For concrete repair and protection products, Amstelfy covers surface protection systems for concrete in its ISO/IEC 17025-accredited laboratory (NAC-037-TL). Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 1504-2 is the harmonised standard for products that protect the concrete surface: hydrophobic impregnations that line the pores and repel water, impregnations that fill the pores, and coatings that form a continuous film. It links each product to the principles it can serve, protection against ingress, moisture control, physical and chemical resistance and increasing resistivity, and lists the performance characteristics to be declared for each intended use: permeability to water vapour, carbon dioxide and liquid water, capillary absorption, adhesion by pull-off, crack bridging, abrasion and impact resistance, resistance to severe chemical attack, thermal compatibility, depth of penetration for impregnations, drying rate and reaction to fire. Conformity follows type testing plus factory production control; the AVCP system depends on use and fire performance.

    Type testing and factory production control

    A type-testing programme selects the characteristics for the declared principles and applies the referenced methods: capillary absorption and permeability to water to EN 1062-3, water vapour permeability to EN ISO 7783, carbon dioxide permeability to EN 1062-6, adhesion to EN 1542 on reference concrete, crack bridging ability to EN 1062-7 in static or dynamic classes, impact resistance to EN ISO 6272-1 in three classes, abrasion to EN ISO 5470-1, thermal compatibility to EN 13687-1 or its sibling parts, and chemical resistance by immersion. Hydrophobic impregnations are tested for penetration depth, water absorption and alkali resistance, and drying rate. FPC covers raw materials, batch records and finished-product identity tests.

    What the report states

    The report gives each measured characteristic against the class or limit in the standard, for example adhesion of at least 1.0 MPa for rigid systems without traffic and 2.0 MPa with traffic, crack bridging class, impact class, permeability values and the thermal compatibility result, together with the product type and intended principles. These become the declared performances in the DoP.

    Where the result is required

    CE marking of anti-carbonation coatings, car park deck coatings, silane and siloxane treatments for bridges and marine structures, pore-filling sealers and chemically resistant linings; specification of protection in repair projects designed under EN 1504-9 principles 1, 2, 5, 6 and 8; and the test evidence owners ask for when they want third-party confirmation of a declared performance.

    What we assess

    • surface protection systems for concrete

    Products covered

    • concrete repair and protection products

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    A silane or siloxane impregnation is tested for depth of penetration, water absorption and resistance to alkali, drying rate and loss of mass after freeze–thaw with salt, since it forms no film. A coating is tested for permeabilities, adhesion, crack bridging, abrasion and impact, and thermal compatibility, because it must stay intact as a layer.

    By pull-off to EN 1542: rigid systems need at least 1.0 MPa without trafficking and 2.0 MPa with trafficking; flexible systems need 0.8 MPa and 1.5 MPa respectively, each with a lower limit for the smallest single value. The same minima apply after thermal compatibility cycling.

    No. It is declared when the coating is intended to bridge cracks, as on decks and facades with live cracks. EN 1062-7 gives static classes A1 to A5 by crack width at a given temperature and dynamic classes B1 to B4.2 by cyclic crack movement. Otherwise the characteristic is declared as no performance determined.

    Related standards

    All Concrete, fibres, mortars & concrete repair products testing