European Assessment Document
EAD 340275-00-0104 - Externally-bonded composite systems with inorganic matrix (FRCM) for strengthening of concrete and masonry structures
In short
EAD 340275-00-0104 is the EOTA European Assessment Document for externally-bonded composite systems with inorganic matrix (frcm) for strengthening of concrete and masonry structures. Amstelfy Technical Solutions tests FRCM / TRM strengthening systems against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): tensile behaviour of the composite, bond to substrate, durability (freeze-thaw, alkaline, salt, humidity) and fire and high-temperature behaviour (where claimed). The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.
What the EAD assesses
EAD 340275-00-0104 covers externally bonded composite systems in which a mesh of carbon, glass, basalt, aramid, PBO or steel cords is embedded in an inorganic matrix, usually a cement- or lime-based mortar, applied in thin layers to concrete or masonry. Unlike epoxy-bonded FRP, the matrix cracks under tension at low strain, so the composite behaves in three stages: uncracked, crack formation, and a cracked stage governed by the mesh. The assessment therefore centres on the tensile response of the FRCM coupon, the bond between the composite and the substrate, and whether the mesh survives the alkaline matrix and the outdoor environment. The system is assessed as a kit of defined mesh and defined mortar; changing either requires a new assessment. The ETA gives the design-relevant tensile and bond parameters per substrate.
Assessment programme
The mesh is characterised for geometry, mass per unit area and tensile properties of the yarns or cords. The mortar is tested for flexural and compressive strength and for adhesion to the substrate. FRCM coupons are cast with the mesh centred in the matrix, cured, and pulled in tension between clamped or clevis-type grips while strain is measured over the central length, producing the full stress-strain curve. Bond is tested by single- or double-lap shear on masonry and concrete prisms, recording load, slip and failure plane. Durability series expose coupons to freeze-thaw, alkaline and saline solutions and humidity before re-testing, and residual behaviour after exposure to high temperature is determined where the manufacturer claims it.
What the report states
The report gives the tensile curve parameters: cracking stress and strain, cracked-stage modulus, ultimate stress and strain expressed on the dry mesh area, together with the crack pattern. Shear bond results state the peak force per unit width, the bond failure mode (matrix-substrate interface, mesh slippage within the matrix, or fibre rupture) and the conventional design strain. Mortar strengths and all retained properties after conditioning are listed with the number of specimens.
Where the result is required
FRCM is specified where epoxy-based FRP is unsuitable: historic masonry needing vapour permeability, structures with fire requirements, damp substrates and seismic retrofits of walls, vaults and columns. The declared parameters are the inputs for CNR-DT 215 and the RILEM TC 250-CSM design recommendations, and an ETA is increasingly asked for in Italian, Greek and Portuguese public tenders. Manufacturers serving the United States run the ICC-ES AC434 programme on the same system; the coupon tensile and bond concepts are related but the acceptance rules differ.
What we assess
- tensile behaviour of the composite
- bond to substrate
- durability (freeze-thaw, alkaline, salt, humidity)
- fire and high-temperature behaviour (where claimed)
Products covered
- FRCM / TRM strengthening systems
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | Yes |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EAD 331668-00-0601 - Glass, basalt, aramid, carbon, PBO and steel rovings for fibre-reinforced anchor spikes
- ICC-ES AC320 - Acceptance criteria for fiber-reinforced polymer composite or unreinforced polymer connectors anchored in concrete
- EAD 340351-00-0104 - Fibre reinforced polymer kits made of a pultruded carbon fibre laminate and an epoxy adhesive
- EAD 340352-00-0104 - Fibre reinforced polymer kits made of a carbon or glass fabric and an epoxy resin
- EAD 340392-00-0104 - CRM (composite reinforced mortar) systems for strengthening of concrete and masonry structures
- EAD 260023-00-0301 - Carbon, glass, basalt and aramid fibre reinforced polymer bars as reinforcement of structural elements
- EAD 260001-00-0303 - Structural sections made from fibre reinforced polymers (FRP / glass fibre composites)