Harmonised or product standard

    EN 1504-8 - Products and systems for the protection and repair of concrete structures - part 8: quality control and evaluation of conformity (AVCP)

    Testing · NAC-037-TL

    In short

    EN 1504-8 - Products and systems for the protection and repair of concrete structures - part 8: quality control and evaluation of conformity (AVCP). For concrete repair and protection products, Amstelfy covers quality control and evaluation of conformity (AVCP) in its ISO/IEC 17025-accredited laboratory (NAC-037-TL). Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 1504-8 sets out how conformity of products covered by EN 1504-2 to EN 1504-7 is evaluated and maintained. It describes the manufacturer's factory production control system, the initial type testing that establishes declared performance, the identification tests that confirm a production batch is the same product that was type tested, and the sampling, frequencies and records that go with them. It also explains how the assessment and verification of constancy of performance systems named in the Annex ZA of each product part are applied, from manufacturer-only control to third-party certification of the FPC for structural uses. The part has no performance requirements of its own; it is the quality framework around the test results of the other parts.

    Type testing and factory production control

    Applying EN 1504-8 starts with a product dossier: formulation, constituents and their specifications, process description and the type-test reports. Identification characteristics are then chosen from the lists in the standard appropriate to the binder, for example infrared spectrum, density, viscosity, grading, loss on ignition, ash content or workable life, and tested at the stated minimum frequencies on production samples. Performance characteristics are retested at the intervals the standard prescribes or when raw materials or process change. Records, calibration, handling of non-conforming product and traceability of batches are documented in the quality manual. A certification audit reviews this system and witnesses or samples for testing.

    What the report states

    Identification and performance tests on production samples are reported against the type-test fingerprint and declared values, giving the manufacturer evidence of constancy for each batch and the documentation an auditor or Notified Body expects. Where the product part is covered by a voluntary ISO/IEC 17065 scheme, these laboratory results and the FPC review support the certificate that confirms conformity of production.

    Where the result is required

    Setting up and auditing factory production control for mortars, coatings, adhesives, injection and anchoring products placed on the EEA market under EN 1504-2 to EN 1504-7, preparing for the Notified Body certification required by AVCP system 2+ for structural uses, batch release testing, and voluntary product certification requested by public owners or in tender prequalification.

    What we assess

    • quality control and evaluation of conformity (AVCP)

    Products covered

    • concrete repair and protection products

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    An identification test is a quick fingerprint of the product, such as density, infrared spectrum, grading or viscosity, performed on every production batch or at a set frequency. It shows that the batch is the same formulation that passed the type tests, without repeating the long performance tests each time.

    Each product part states it in Annex ZA. Products for structural uses are generally under system 2+, requiring Notified Body certification of the factory production control, while non-structural uses are under system 4, where the manufacturer alone declares. Reaction to fire can add system 1 or 3 for the fire characteristic.

    Testing can establish the type-test values and the identification fingerprints that the FPC compares against, and for product parts covered by a voluntary ISO/IEC 17065 scheme a certification audit reviews the control system. Formal certification of constancy of performance for CE marking under system 2+ remains the role of a Notified Body.

    Related standards

    All Concrete, fibres, mortars & concrete repair products testing