Harmonised or product standard

    EN 1504-4 - Products and systems for the protection and repair of concrete structures - part 4: structural bonding

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 1504-4 - Products and systems for the protection and repair of concrete structures - part 4: structural bonding. For concrete repair and protection products, Amstelfy covers structural bonding in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 1504-4 is the harmonised standard for adhesives and bonding agents that transfer structural load across a joint in concrete: bonding steel or FRP plates to concrete for strengthening, bonding hardened concrete to hardened concrete, bonding fresh concrete to hardened concrete and bonding of precast segments. Because such products carry force permanently, the standard emphasises bond strength under shear and tension, stiffness and thermal behaviour of the cured adhesive, workability and open time, and durability under moisture and temperature. Characteristics include slant shear and tensile bond, shear strength to steel, compressive strength and modulus, glass transition temperature, coefficient of thermal expansion, shrinkage, sensitivity to water, durability after thermal and humidity cycling and workable life.

    Type testing and factory production control

    Type testing depends on the intended use. For plate bonding, the adhesive is tested for shear strength on steel-to-steel joints to EN 12188 and for slant shear on concrete prisms to EN 12615, which must fail in the concrete and not at the glue line; for concrete-to-concrete bonding the same slant shear and tensile tests apply, and for fresh-to-hardened bonding EN 12636. The cured adhesive is tested for compressive strength and modulus to EN 12190 and EN 13412, glass transition temperature to EN 12614, thermal expansion to EN 1770, shrinkage to EN 12617 and durability by cycling. Workable life and open time are determined at the stated temperatures. Specimens are prepared at the manufacturer's mixing ratio.

    What the report states

    The report lists each property with its unit against the standard's thresholds, among them compressive strength of at least 30 MPa, modulus in compression of at least 2000 MPa and glass transition temperature of at least 40 °C, and records the failure location of every bond specimen, since a monolithic failure in concrete is the acceptance condition. The declared values enter the DoP and, where requested, a voluntary product certificate.

    Where the result is required

    CE marking of epoxy adhesives for steel and CFRP plate bonding, segmental bridge adhesives, concrete overlays and structural bonding of precast elements; the adhesive component of FRP strengthening kits assessed under EADs 340351 and 340352; and repair designs under EN 1504-9 principle 4, structural strengthening. Owners and engineers specify EN 1504-4 compliance for any load-bearing glued connection.

    What we assess

    • structural bonding

    Products covered

    • concrete repair and protection products

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    The slant shear test loads a glued joint between two concrete halves in combined compression and shear. If the adhesive is adequate, the concrete crushes or shears before the glue line, so the joint behaves monolithically. Failure at the bond line indicates the adhesive or surface preparation is inadequate for structural bonding.

    Above its glass transition the adhesive softens and its stiffness and creep resistance fall sharply. EN 1504-4 requires a Tg of at least 40 °C so that plate-bonded strengthening retains its performance at the surface temperatures reached on facades and roofs. Higher values are declared where the application demands them.

    No. It covers the adhesive or bonding agent. The strengthening kit as a whole, including the CFRP laminate or fabric and its design values, is assessed under the relevant EAD, and the European Technical Assessment is issued by a Technical Assessment Body, which uses EN 1504-4 data for the adhesive.

    Related standards