Harmonised or product standard

    EN 14889-1 - Fibres for concrete - steel fibres - definitions, specifications and conformity

    Certification · NAC-026-PPS

    In short

    EN 14889-1 - Fibres for concrete - steel fibres - definitions, specifications and conformity. For steel fibres, Amstelfy covers certification of conformity and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 14889-1 is the harmonised product standard for steel fibres used in concrete, mortar and grout. Fibres are grouped by manufacturing process: Group I cold-drawn wire, Group II cut sheet, Group III melt-extracted, Group IV shaved cold-drawn wire and Group V milled from blocks. The manufacturer declares length, equivalent diameter and aspect ratio within the tolerances the standard sets, the tensile strength of the fibre material, modulus of elasticity, ductility by a bend test, any coating or galvanising, the effect on consistence of a reference concrete by Vebe time and, for structural use, the effect on concrete strength as the dosage needed to reach the residual flexural strengths of EN 14845-2. Conformity is shown by type testing and factory production control; structural use falls under AVCP system 1 and other uses under system 3.

    Type testing and factory production control

    A certification assessment reviews the type-test file: fibre dimensions on counted samples, tensile strength of the wire or strip, bend test, Vebe time to EN 12350-3 with and without fibres, and EN 14651 beam results from the EN 14845-2 programme that fix the declared dosage. The factory production control is audited for wire or strip supply control, drawing, cutting and deforming process parameters, dimensional and tensile checks at the stated frequencies, glue-collated bundle control where applicable, packaging and traceability. Samples are taken during the audit and tested; the beam, consistence and compressive strength tests sit on the laboratory's testing scope.

    What the report states

    The report confirms each declared characteristic and tolerance, the group and the declared dosage for 1.5 MPa residual strength at CMOD 0.5 mm and 1.0 MPa at 3.5 mm, and the state of the FPC. A voluntary product certificate under the ISO/IEC 17065 scope confirms constancy of production; CE marking for structural use additionally requires the Notified Body certificate of system 1.

    Where the result is required

    Steel fibres for industrial floors, tunnel segments and sprayed linings, precast elements, pile caps and foundations where fibres replace or supplement bar reinforcement, and fibre specifications in design to fib Model Code 2010 and national guidelines. Buyers of fibres use the declared dosage as the direct comparison between products.

    What we assess

    • certification of conformity

    Products covered

    • steel fibres

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028No
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    It is on the ISO/IEC 17065 certification scope NAC-026-PPS; the related test methods are on the ISO/IEC 17025 testing scope.

    Group I cold-drawn wire, the most common hooked-end and crimped fibres; Group II cut from sheet; Group III melt-extracted; Group IV shaved from cold-drawn wire; Group V milled from steel blocks. The group is declared because process affects tensile strength, surface and the tolerances that apply.

    Part 1 covers steel fibres and part 2 polymer fibres. Steel fibres are grouped by manufacturing process and declare wire tensile strength and ductility; polymer fibres are classed by diameter and form and declare polymer, linear density and thermal properties. Both use Vebe time and, for structural fibres, the EN 14845-2 dosage.

    The standard requires the manufacturer to declare the fibre material and any coating, such as galvanising, so the user can judge durability for the exposure class. Uncoated fibres are permitted; surface rust staining on exposed concrete faces is a matter for the concrete specification rather than the fibre standard.

    Related standards