Test method

    EN 12350-3 - Testing fresh concrete - Vebe test

    Testing · NAC-037-TL

    In short

    EN 12350-3 - Testing fresh concrete - Vebe test. Amstelfy's laboratory determines Vebe time of fresh concrete according to EN 12350-3 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN 12350-3 determines

    EN 12350-3 measures the consistence of fresh concrete that is too stiff for the slump test. A slump cone is filled inside a cylindrical container fixed to a vibrating table, the cone is removed, and a transparent disc is lowered onto the top of the concrete. The vibrator is started and the time taken for the concrete to remould itself until the lower surface of the disc is completely in contact with grout is the Vebe time, in seconds. The method is suitable for Vebe times between 5 s and 30 s; shorter times belong to the slump or flow table tests, longer times indicate a mix beyond the range of the test. Because fibres stiffen a mix, it is the method the fibre standards use to quantify their effect on workability.

    Specimens, conditioning and procedure

    A sample is taken under EN 12350-1 and the apparatus is checked for the correct table characteristics and the free movement of the disc guide. The cone is filled in three layers, each compacted with the tamping rod, struck off and lifted vertically; the slump may be noted as supplementary information. The swivel arm is swung over, the disc rested on the concrete, and vibration and stopwatch started together. The operator watches through the disc and stops the clock when the whole underside is covered with cement paste. The test is performed on one sample within the time limit the standard sets after sampling.

    What the report states

    The report gives the Vebe time to the nearest second, the time between sampling and testing, the concrete temperature where relevant and any observation on segregation or fibre balling. For EN 206 purposes the value is placed in the consistence classes V0 to V4; for fibre testing it is reported alongside the value for the same reference concrete without fibres.

    Where the result is required

    Consistence classification of roller-compacted, precast, dry-cast and other stiff concretes under EN 206, and the effect-on-consistence declaration required by EN 14889-1 and EN 14889-2 for steel and polymer fibres, which both specify the Vebe time of a reference concrete with and without the fibre. It also serves as a control test in paving block and pipe production where slump is meaningless.

    What we assess

    • Vebe time

    Products covered

    • fresh concrete

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    When the concrete is so stiff that the slump is near zero or the cone shears, typically for Vebe times above 5 s. Earth-moist precast mixes, roller-compacted concrete and fibre-rich reference mixes fall in this range. For plastic concrete the slump or flow table test is the appropriate method.

    EN 14889-1 and EN 14889-2 require the manufacturer to declare the effect of the fibre on consistence. The Vebe time of a defined reference concrete is measured without fibres and again with the fibres at the declared dosage, and the increase is the declared effect.

    Beyond 30 s the remoulding becomes slow and the end point, full wetting of the disc, is difficult to judge consistently, so the standard limits its applicability. Such a mix is reported as outside the method's range rather than given a questionable number.

    Related standards

    All Concrete, fibres, mortars & concrete repair products testing