Harmonised or product standard

    EN 14889-2 - Fibres for concrete - polymer fibres - definitions, specifications and conformity

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 14889-2 - Fibres for concrete - polymer fibres - definitions, specifications and conformity. For polymer fibres, Amstelfy covers geometry, tensile strength, modulus, effect on concrete in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 14889-2 is the harmonised product standard for polymer fibres used in concrete, mortar and grout. It classifies fibres into Class Ia, micro fibres in monofilament form with a diameter below 0.30 mm, Class Ib, micro fibres in fibrillated form, and Class II, macro fibres above 0.30 mm diameter. It defines the characteristics the manufacturer declares: polymer type, length, equivalent diameter, linear density, tensile strength, modulus of elasticity, melting and ignition behaviour, effect on consistence and, for structural use, effect on concrete strength. Conformity is demonstrated by initial type testing and continuous factory production control; the assessment system depends on whether the fibre is intended for structural use, where residual strength matters, or for other uses such as plastic shrinkage control.

    Type testing and factory production control

    Type testing covers fibre identification and geometry on counted samples, tensile strength and modulus on filaments or strands by the methods the standard calls up, density and thermal properties, and the Vebe time of a reference concrete with and without the fibre under EN 12350-3. For Class II fibres declared for structural use, the effect on concrete strength is determined under EN 14845-2 using EN 14651 beams. Factory production control must cover raw polymer, extrusion and cutting process parameters, fibre dimensions and packaging, with records and test frequencies set out in the standard. Product certification adds surveillance of this control system and periodic sample testing.

    What the report states

    A type-test report states each declared characteristic with its measured value and tolerance compliance, the class, and for structural fibres the dosage giving fR,1 of 1.5 MPa and fR,4 of 1.0 MPa. These feed the Declaration of Performance and CE marking. A voluntary product certificate confirms continuing conformity of production against the standard.

    Where the result is required

    CE marking of micro and macro synthetic fibres sold in the EEA for crack control, fire spalling resistance of tunnel concrete, slabs on grade, shotcrete and precast products; procurement specifications that call for EN 14889-2 Class II fibres with a declared structural effect; and the European documentation that accompanies ASTM D7508 and C1116 data when a fibre is marketed on both sides of the Atlantic.

    What we assess

    • geometry, tensile strength, modulus, effect on concrete

    Products covered

    • polymer fibres

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    Fibres declared for structural use fall under system 1, with a Notified Body certifying constancy of performance; fibres for other uses fall under system 3, where a notified laboratory performs the type testing. Voluntary product certification is separate from both and does not replace the notified-body role.

    Class Ia and Ib are micro fibres below 0.30 mm diameter, monofilament and fibrillated respectively, used mainly to control plastic shrinkage cracking and explosive spalling in fire. Class II macro fibres exceed 0.30 mm and are the only class for which a structural effect on concrete strength is declared.

    Polymer fibres are not subject to corrosion, so the standard addresses stability through the declared polymer type and the melting and ignition points of the material rather than through ageing tests of the concrete. Any additional durability claim is supported by separate evidence outside the standard.

    Related standards

    All Concrete, fibres, mortars & concrete repair products testing