Test method

    ISO 14601-1 - Alkali test (as listed on the scope)

    Testing · NAC-037-TL

    In short

    ISO 14601-1 - Alkali test (as listed on the scope). Amstelfy's laboratory determines alkali resistance of GRC / glass fibres according to ISO 14601-1 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What ISO 14601-1 determines

    The accreditation scope lists ISO 14601-1 as an alkali test for glass fibres and glass-fibre reinforced cement. The purpose of an alkali test in this context is to show whether the reinforcing glass withstands the highly alkaline pore solution of a cementitious matrix, which attacks ordinary E-glass and is the reason alkali-resistant glass with a high zirconia content is used in GRC. Specimens of fibre, strand or composite are exposed to an alkaline environment representative of cement for a defined time and temperature, and the property of interest, typically strength, is measured afterwards and compared with unexposed control specimens. The retained fraction indicates the durability of the fibre in the matrix.

    Specimens, conditioning and procedure

    The client and the laboratory agree the specimen form, fibre strands, yarn or GRC coupons, the exposure medium and the temperature and duration, following the method as it is written on the scope and the referencing product specification. Control specimens are kept unexposed under the same ambient conditions. After exposure, specimens are rinsed, dried or conditioned as the method requires and tested, usually in tension for fibres or in bending for GRC coupons, under the same conditions as the controls. The number of specimens per condition follows the referencing specification.

    What the report states

    The report gives the measured property before and after exposure, the retained value in percent, the exposure conditions actually applied, the specimen form and any visual change such as surface attack or embrittlement. The client compares the retention with the limit in the fibre or GRC specification being used.

    Where the result is required

    Qualification of alkali-resistant glass fibres and rovings for GRC and cement-based renders, incoming-material checks under EN 1169 factory production control, and durability evidence for glass fibre products in cementitious systems such as reinforcing meshes. It complements the mechanical tests of EN 1170 by addressing the long-term stability of the reinforcement.

    What we assess

    • alkali resistance

    Products covered

    • GRC / glass fibres

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Cement pore water has a pH above 12.5. Ordinary glass loses strength quickly in such a solution, so GRC relies on alkali-resistant glass. An alkali test confirms that the fibre delivered keeps its strength in that environment, which the fresh mechanical properties of the composite cannot show.

    The specimen form, the exposure medium, temperature and duration, the property to be measured afterwards and the number of specimens, all taken from the method as listed and from the specification the result will serve. These choices determine comparability with earlier data.

    The report gives a retained property value. Whether that constitutes a pass depends on the limit in the fibre or GRC specification the client applies, which the report quotes alongside the result when the client provides it.