Harmonised or product standard

    EN 1169 - Precast concrete products - general rules for factory production control of glass-fibre reinforced cement

    Certification · NAC-026-PPS

    In short

    EN 1169 - Precast concrete products - general rules for factory production control of glass-fibre reinforced cement. For GRC products, Amstelfy covers FPC certification and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 1169 lays down the general rules for factory production control of glass-fibre reinforced cement products, the thin cementitious composites reinforced with alkali-resistant glass fibre that are used for cladding, formwork, channels and architectural elements. It specifies what the manufacturer must control at each stage: the constituents, cement, sand, AR glass fibre, polymers and admixtures, with their specifications and incoming checks; the production process, whether sprayed or premixed, including mix proportions, fibre content and length, spray equipment calibration and board thickness; the curing regime; and the finished product, through tests on test boards made alongside production using the EN 1170 methods. It defines minimum test frequencies, documentation, equipment calibration and the handling of non-conforming product, and provides the basis on which a certification body assesses a GRC plant.

    Type testing and factory production control

    A certification assessment reviews the plant's FPC manual against the standard: supplier certificates and acceptance tests for fibres and cement, records of fibre content checks by the wash-out test on fresh GRC, bending tests for LOP and MOR, density and water absorption on coupons from test boards, thickness and dimensional control of products, and curing records. Test boards are sampled during the audit and tested under EN 1170 in the laboratory. The audit covers calibration of spray guns and fibre choppers, traceability of batches to products and the corrective-action system. Surveillance repeats the review and sampling at defined intervals.

    What the report states

    The assessment report states whether each element of EN 1169 is implemented, lists the test results on the sampled boards against the manufacturer's declared grade, and identifies any non-conformities with the agreed corrective actions. On a positive outcome a voluntary product certificate is issued for the GRC production under the laboratory's ISO/IEC 17065 scope.

    Where the result is required

    Third-party certification of GRC manufacturers supplying facade panels, permanent formwork, drainage channels and street furniture; prequalification demanded by main contractors and facade consultants; and the quality evidence that accompanies project-specific testing of GRC to EN 1170. In countries with GRC product standards or trade-association quality schemes the EN 1169 FPC is the common foundation.

    What we assess

    • FPC certification

    Products covered

    • GRC products

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028No
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    It is on the ISO/IEC 17065 certification scope NAC-026-PPS; the related test methods are on the ISO/IEC 17025 testing scope.

    Fibre content of the fresh GRC by wash-out at a frequency tied to production, bending tests on coupons from test boards for LOP and MOR, dry density and water absorption, thickness checks on products, and checks of fibre length and spray equipment. The frequencies depend on output and are stated in the standard.

    Yes. The standard covers both processes. For premix, control focuses on fibre dosing into the mixer, mixing time and casting or vibration; for spray-up it adds fibre chopper calibration, slurry and fibre output rates and layer build-up. The finished-product tests are the same EN 1170 methods.

    No. EN 1169 is not a harmonised product standard and GRC elements are not CE marked under it. The certificate is a voluntary third-party confirmation that the factory production control meets the standard and that sampled products achieve the declared grade, which clients and specifiers can request.

    Related standards

    All Concrete, fibres, mortars & concrete repair products testing