Test method

    EN 1170 - Precast concrete products - test methods for glass-fibre reinforced cement (GRC)

    Testing · NAC-037-TL

    In short

    EN 1170 - Precast concrete products - test methods for glass-fibre reinforced cement (GRC). Amstelfy's laboratory determines flexural strength (LOP, MOR), density, water absorption, fibre content of GRC according to EN 1170 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN 1170 determines

    EN 1170 is a series of test methods for glass-fibre reinforced cement, the thin-section composite of cement mortar and alkali-resistant glass fibre used for cladding panels, formwork and architectural elements. The parts on the accreditation scope cover the properties that control GRC quality: the complete bending test, which loads a coupon in four-point bending to obtain the limit of proportionality, LOP, where the matrix first cracks, and the modulus of rupture, MOR, the maximum flexural stress carried by the fibres after cracking; the determination of dry density and water absorption by immersion and drying; and the fibre content of fresh GRC by washing out the fibres from a known mass and of sprayed GRC from a cut test piece. Together they describe matrix quality, fibre dosage and the mechanical class of the product.

    Specimens, conditioning and procedure

    Test boards are sprayed or cast alongside production and coupons are cut from them in the orientations the method requires, then conditioned as the relevant part prescribes before testing. In the bending test the coupon is supported on two rollers and loaded through two inner rollers at a controlled rate while load and deflection are recorded; LOP and MOR are calculated from the load–deflection curve and the measured section. Density and absorption specimens are weighed saturated, suspended and oven-dry. The wash-out test separates fibres from a weighed sample of fresh GRC, dries and weighs them. The client specifies which parts are needed and the ages.

    What the report states

    The report gives LOP and MOR in MPa for each coupon with the mean, the deflection at failure if requested, dry density in kg/m³, water absorption in percent by mass and fibre content in percent by mass of the fresh or hardened GRC, each with the specimen origin, conditioning and age. Results are compared with the manufacturer's declared grade or project specification.

    Where the result is required

    Factory production control and type testing of GRC under EN 1169, product classification by LOP and MOR, acceptance testing of cladding and architectural panels, formwork and permanent shuttering, and verification of fibre dosage during spraying. Designers use LOP as the serviceability limit and MOR as the ultimate flexural reference for GRC elements.

    What we assess

    • flexural strength (LOP, MOR), density, water absorption, fibre content

    Products covered

    • GRC

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    LOP is the stress at which the load–deflection curve departs from linearity, marking first cracking of the cement matrix; it governs serviceability. MOR is the maximum flexural stress reached after cracking, carried largely by the glass fibres, and represents the ultimate bending capacity of the composite.

    The scope covers the bending test, dry density and water absorption, and fibre content of fresh and sprayed GRC. The combination follows EN 1169 for production control or the project specification for acceptance testing. Specimen boards, conditioning and ages are agreed before testing.

    Test boards sprayed in the same session reproduce the production process while giving flat specimens of controlled thickness and orientation. Coupons from finished panels are possible for investigations, but curved shapes, ribs and facing mixes make them less representative and the results less comparable.

    Related standards

    All Concrete, fibres, mortars & concrete repair products testing