Test method

    EN 1931 - Flexible sheets for waterproofing - water vapour transmission properties

    Testing · NAC-037-TL

    In short

    EN 1931 - Flexible sheets for waterproofing - water vapour transmission properties. Amstelfy's laboratory determines water vapour transmission properties of bitumen, plastic and rubber sheets according to EN 1931 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN 1931 determines

    EN 1931 determines the water vapour transmission properties of flexible waterproofing sheets: how readily water vapour diffuses through the membrane. A specimen is sealed over a cup so that a humidity difference exists across it, the assembly is kept at constant temperature and humidity, and the change in mass is followed until the rate becomes constant. From the steady rate, the exposed area and the thickness, the water vapour transmission rate, the water vapour resistance factor relative to still air and the equivalent air layer thickness sd are calculated. These quantities decide the role of a sheet in a roof or wall build-up: a vapour control layer needs a high sd value, a breather membrane or underlay a low one. The method covers bitumen, plastic and rubber sheets.

    Specimens, conditioning and procedure

    Circular specimens are cut from the sheet away from the edges, their thickness measured and their faces identified. Each specimen is sealed over a cup containing the desiccant or solution that fixes the humidity on one side, using a sealant or clamping arrangement that prevents leakage at the rim. The assemblies are placed in a chamber at the temperature and relative humidity the standard specifies and weighed at intervals until successive weighings show a constant rate of mass change. Blank cups correct for any uptake by the sealant. The transmission rate per unit area and time is calculated from the slope, and the resistance factor and sd value follow from it using the thickness and the vapour permeability of air.

    What the report states

    The report states the water vapour transmission rate in mass per unit area and time, the dimensionless water vapour resistance factor and the sd value in metres, as the mean of the specimens with the test conditions, thickness and the time to steady state. Product standards have the manufacturer declare the sd value or the resistance factor in the Declaration of Performance, with the tolerance the standard allows.

    Where the result is required

    Cited by EN 13859-1 and EN 13859-2 for underlays and breather membranes, where a low sd value is the selling point, by EN 13970 and EN 13984 for vapour control layers, where the sd value is high, and by EN 13707, EN 13956, EN 13967 and EN 13969 for roofing and damp proof sheets. The values feed hygrothermal design to EN ISO 13788 and dynamic moisture simulations, and the method is also used to characterise liquid-applied films and tapes for the same purpose.

    What we assess

    • water vapour transmission properties

    Products covered

    • bitumen, plastic and rubber sheets

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    The transmission rate is the measured quantity: mass of vapour through unit area per unit time under the test gradient. The resistance factor μ compares the sheet with a layer of still air of the same thickness. The sd value multiplies μ by the thickness and gives the thickness of still air with the same resistance, which is the figure used in condensation calculations and in product declarations.

    Until the mass change is steady, which depends on how tight the sheet is: a breather membrane reaches a constant rate within days, a bitumen vapour control layer with foil may need weeks because the mass change per weighing is tiny. The time to steady state is stated in the report, and highly resistant sheets are scheduled first in a type-testing programme.

    For a homogeneous sheet, no. For a coated, laminated or textured sheet the result can depend on which face sees the humid side, so the standard asks for the specimen orientation to be recorded, and product standards may specify it. The report states which face was towards the high humidity so that the value is applied correctly in the build-up.

    Related standards