European Assessment Document

    EAD 220069-00-0402 - Flat and profiled plastic roofing sheets made of recycled material for fully supported discontinuous roofing

    Testing · NAC-037-TLCertification · NAC-026-PPSETA route

    In short

    EAD 220069-00-0402 is the EOTA European Assessment Document for flat and profiled plastic roofing sheets made of recycled material for fully supported discontinuous roofing. Amstelfy Technical Solutions tests recycled-plastic roofing sheets and tiles against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): mechanical resistance and impact, watertightness, dimensional stability and durability and ageing. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.

    What the EAD assesses

    EAD 220069-00-0402 covers flat and profiled sheets and tiles made of recycled plastics, used as the outer layer of a discontinuous roof covering that is fully supported by a continuous deck rather than spanning between battens. Recycled feedstock varies, so the EAD is built around proving that a defined, controlled raw-material specification gives a stable product. The essential characteristics are those expected of a roof covering: mechanical resistance under point and distributed loads, resistance to impact, watertightness of the covering including its overlaps, dimensional stability and behaviour at high and low temperature, durability against UV, heat and freeze-thaw, reaction to fire and external fire performance, and release of dangerous substances. The assessment combines identification of the material, performance tests on the product and repeat tests on aged specimens.

    Assessment programme

    The manufacturer supplies products from normal production together with the recycled-material specification, additive package and the laying instructions, including overlaps, fixings and the supporting deck. Identification tests on the material fix a fingerprint that factory production control can check later. Performance tests load the product on the intended deck, drop an impactor onto it at ambient and low temperature, apply water to a laid-up section to check that joints and overlaps shed water, and measure dimensional change after heat exposure. Durability specimens are weathered in UV and water cycles, heat aged and freeze-thaw cycled where the use category requires it, and the mechanical and impact tests are repeated on them. Fire tests follow the European classification methods.

    What the report states

    The report states the identified material properties, load and impact results before and after ageing, the outcome of the watertightness check on the laid covering, dimensional changes in per cent, and reaction-to-fire and roof fire classes where tested. The Technical Assessment Body uses the file for the ETA; the manufacturer declares the ETA values in the Declaration of Performance and keeps the material fingerprint for factory production control.

    Where the result is required

    Recycled-plastic roofing products fall outside the harmonised standards for clay, concrete and fibre-cement roofing, so an ETA on this EAD is the route to CE marking in the EU and EEA. Typical users are manufacturers of slate-look tiles, profiled sheets for sheds and agricultural buildings and lightweight tiles for renovation. Procurement questions about recycled content are usually answered with the same material specification that the assessment relies on.

    What we assess

    • mechanical resistance and impact
    • watertightness
    • dimensional stability
    • durability and ageing

    Products covered

    • recycled-plastic roofing sheets and tiles

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    No. ETAs are issued by Technical Assessment Bodies designated under the CPR. Amstelfy carries out the assessment tests in its accredited laboratory, prepares the test reports to the EAD's clause structure and coordinates the test plan with the TAB of your choice.

    Yes. The product is only as stable as its feedstock, so the assessment fixes a material specification, including the recycled fraction and additives, and identifies the material in the laboratory. Changing the source of recyclate later means showing, through factory production control and if necessary re-testing, that the new material still matches the specification assessed.

    The sheets or tiles are tested on a continuous deck of the type named in the installation instructions, not spanning between battens. Point-load, impact and walkability tests therefore measure the resistance of the product over a stiff support, and the installation instructions in the ETA are limited to that support condition.

    Products of each profile and colour family to be covered, from one documented production run, plus the fixings and accessories needed to lay a test section with the specified overlaps. Dark and light colours age differently under UV and heat, so the programme is usually run on the colours at the extremes of the range.

    Related standards

    All Waterproofing membranes, roof underlays & liquid-applied systems testing