Harmonised or product standard

    EN 15814 - Polymer modified bituminous thick coatings for waterproofing - definitions and requirements

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 15814 - Polymer modified bituminous thick coatings for waterproofing - definitions and requirements. For PMBC basement waterproofing coatings, Amstelfy covers watertightness, crack bridging, water resistance and flexibility at low temperature in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 15814 is the harmonised product standard for polymer modified bituminous thick coatings, bitumen emulsions applied by trowel or spray in thick layers to waterproof basement walls and foundations against soil moisture and water. The standard defines the product, its application thickness and the performance classes a manufacturer declares: crack bridging (CB0, CB1, CB2), watertightness (W1, W2A, W2B) and resistance to compression (C classes), supported by flexibility at low temperature, dimensional stability at high temperature, water resistance, resistance to rain during drying and the reduction in thickness on drying that links wet to dry film. The coating is tested as applied to a substrate, so application thickness, curing conditions and any reinforcement fabric are part of the specimen. Type testing plus factory production control support the Declaration of Performance.

    Type testing and factory production control

    Specimens are produced by applying the coating at the declared dry film thickness onto the substrates the test standards specify, and curing them under standard conditions until fully dry. Crack bridging is tested by opening a crack under the cured coating at low temperature until the film tears. Watertightness places the coating over a slot and applies water pressure for the period in EN 15820. Flexibility at low temperature bends a coated specimen around a mandrel in the cold, dimensional stability stores a coated plate vertically in heat and checks for sliding, water resistance immerses specimens and looks for softening, swelling and detachment, and resistance to rain exposes a freshly applied coat to water spray after the claimed drying time.

    What the report states

    The report assigns the classes: CB0, CB1 or CB2 for crack bridging, W1, W2A or W2B for watertightness and the compression class, and reports pass or fail for cold flexibility, heat stability, water resistance and rain resistance, with the rain-resistance time in hours after application and the ratio of dry to wet thickness. The manufacturer declares these in the Declaration of Performance and uses the thickness ratio in the application instructions.

    Where the result is required

    EN 15814 is the CE-marking standard for PMBC products across the EU and EEA and the basis of national basement waterproofing rules such as the German DIN 18533 series, which select coatings by CB and W class for different water loads. Users include manufacturers of bitumen emulsions, waterproofing contractors specifying for cellars and plinths, and producers of complementary products such as reinforcement fabrics and protection boards. The individual methods EN 15813, EN 15816, EN 15817, EN 15818 and EN 15820 are also run on their own for development and FPC.

    What we assess

    • watertightness
    • crack bridging
    • water resistance
    • flexibility at low temperature
    • dimensional stability at high temperature
    • resistance to rain

    Products covered

    • PMBC basement waterproofing coatings

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    The watertightness classes describe the water load the coating withstood in the EN 15820 slot test; W1 is the lowest class and W2B the highest. National application rules map these classes to soil moisture, non-pressing water and pressing water situations, so the class you need follows from the water load your product is sold for, not from the test alone.

    Crack bridging and watertightness over a slot depend on how the coating distributes strain, and many systems rely on an embedded fleece or mesh to reach CB2 or W2B. The classes are therefore valid only for the build-up tested, including fabric, number of coats and dry thickness, and the Declaration of Performance should name that build-up.

    Enough material from one batch to apply all specimens at the declared thickness with spare for retests, plus the reinforcement fabric if used, the primer, mixing ratio for two-component products, and the data sheet with the wet thickness per coat and drying time. Specimens are made in the laboratory so that the application is documented.