European Assessment Document

    EAD 030350-00-0402 - Liquid applied roof waterproofing kits

    Testing · NAC-037-TLCertification · NAC-026-PPSETA route

    In short

    EAD 030350-00-0402 is the EOTA European Assessment Document for liquid applied roof waterproofing kits. Amstelfy Technical Solutions tests liquid applied roofing membranes (PU, PMMA, acrylic, bitumen) against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): watertightness, resistance to wind load, impact and indentation, fatigue movement and artificial ageing (UV, heat, water). The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.

    What the EAD assesses

    EAD 030350-00-0402 replaced ETAG 005 as the assessment basis for liquid applied roof waterproofing kits: the liquid component plus any primer, reinforcement fleece, surfacing and detailing products that together form the membrane on the roof. It assesses the kit against categories the manufacturer selects: expected working life (W1, W2 or W3, that is 5, 10 or 25 years), climatic zone (moderate or severe), user load (P1 to P4), roof slope and the lowest and highest surface temperatures (TL and TH classes). Each category decides which tests apply and how severe the ageing is. The essential characteristics cover watertightness, resistance to wind load, impact and static indentation, fatigue movement over moving substrates, slipperiness, reaction to fire, external fire performance and the durability of all of these after heat, UV and water ageing.

    Assessment programme

    The manufacturer applies the kit to the substrates it is intended for, at the minimum declared thickness. Reference tests establish watertightness, tensile adhesion to the substrate (the basis of the wind-load assessment), resistance to dynamic indentation under a falling punch and to static indentation under a loaded ball, and fatigue movement, in which the membrane bridges a joint that is opened and closed repeatedly at the lowest surface temperature of the claimed TL class. Durability is checked by repeating key tests after heat ageing, UV exposure with water and immersion in hot water for periods that grow with the working-life category. Slip resistance is added for kits that will be walked on, and fire tests where a class is claimed.

    What the report states

    The report gives every characteristic in the form the EAD prescribes: watertight or not at the stated pressure, tensile adhesion to the substrate before and after ageing, the drop height or load at which indentation no longer causes leakage, fatigue cycles completed without cracking, and the categories (W, M or S, P, S, TL, TH) the evidence supports. The Technical Assessment Body transfers these into the ETA; the manufacturer then declares them in the Declaration of Performance.

    Where the result is required

    Every liquid applied roof waterproofing kit that is CE marked needs an ETA based on this EAD, because no harmonised product standard covers PU, PMMA, polyurea, acrylic or bitumen-emulsion liquid membranes. The same programme is used by manufacturers who want a third-party technical file for tenders outside the EU, and by producers of liquid detailing products sold alongside sheet membranes. The sheet-membrane methods EN 1928, EN 12691 and EN 12730 share the same physical principles, which helps when a client compares a liquid kit with a sheet system.

    What we assess

    • watertightness
    • resistance to wind load, impact and indentation
    • fatigue movement
    • artificial ageing (UV, heat, water)
    • slipperiness

    Products covered

    • liquid applied roofing membranes (PU, PMMA, acrylic, bitumen)

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    No. ETAs are issued by Technical Assessment Bodies designated under the CPR. Amstelfy carries out the assessment tests in its accredited laboratory, prepares the test reports to the EAD's clause structure and coordinates the test plan with the TAB of your choice.

    Choose the categories you can support commercially and technically. W3 (25 years) needs the longest ageing, P3 and P4 add slip resistance and heavier indentation loads, and a high TH class raises the temperature at which ageing and heat tests are run. Applying for everything inflates the programme; applying for too little limits where the ETA can be used.

    Enough of each kit component from one production batch to apply all specimens at the minimum declared thickness, the application instructions, the list of substrates and primers to be covered, and any reinforcement or surfacing that belongs to the kit. Specimens are prepared in the laboratory or witnessed, so that the application is documented in the report.

    The EAD calls up its own procedures, many of them EOTA Technical Reports derived from the sheet-membrane methods. Results obtained under EN 1928 or EN 12691 for a sheet product cannot be transferred to a liquid kit. The physical principle is the same, however, which helps when reading older data on a comparable thickness.

    Related standards

    All Waterproofing membranes, roof underlays & liquid-applied systems testing