Harmonised or product standard
EN 13859-2 - Flexible sheets for waterproofing - underlays for walls
In short
EN 13859-2 - Flexible sheets for waterproofing - underlays for walls. For wall underlays / breather membranes, Amstelfy covers watertightness, tensile and tear, vapour resistance and ageing in its ISO/IEC 17025-accredited laboratory (NAC-037-TL). Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.
What the standard covers
EN 13859-2 is the harmonised product standard for flexible underlays fixed on the outside of a wall and covered by a cladding: the breather membranes of timber-frame and masonry-cavity walls. The membrane has two jobs, to drain water that gets past the cladding and to let vapour out of the wall, so the standard pairs a water penetration class with a declared sd value. Around these it adds tensile strength and elongation, nail-shank tear resistance, cold flexibility, dimensional stability, straightness, mass per unit area and reaction to fire, and requires water penetration and tensile strength to be repeated after an ageing sequence of UV and heat. The standard assumes the membrane is covered; permanently UV-exposed use behind open-jointed cladding is outside it. Conformity rests on type testing plus factory production control and ends in a Declaration of Performance.
Type testing and factory production control
Specimens come from one roll in both directions. The water penetration test applies a small head of water to the upper face and looks for passage to the underside; the vapour test seals the membrane over a cup and follows the mass change until it is steady, giving the sd value. Strip specimens are pulled to failure for strength and elongation and pierced with a nail for tear resistance; a strip is bent at low temperature. Ageing exposes a second set of specimens to UV radiation and water and then to heat, after which penetration and tensile tests are repeated. Reaction to fire goes through the European classification. Factory production control repeats the roll checks and key tests.
What the report states
The report gives the water penetration class before and after ageing, the sd value in metres, maximum tensile force in N per 50 mm and elongation in per cent for both directions, nail tear force in N, the cold-bend result, dimensional stability and the fire class. Each declared characteristic is written as the manufacturer's declared value with the tolerance the standard permits, ready for the Declaration of Performance.
Where the result is required
EN 13859-2 is the CE-marking standard for breather membranes and wall underlays in the EU and EEA. Timber-frame manufacturers, facade contractors and cladding system suppliers specify by its declared values: a low sd value for vapour-open walls, W1 for exposed sites, high nail tear for membranes stapled to studs. Membranes for open-jointed rainscreens, which need permanent UV resistance, are assessed under an EAD instead, and the same test data forms the starting point.
What we assess
- watertightness
- tensile and tear
- vapour resistance
- ageing
Products covered
- wall underlays / breather membranes
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | No |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EAD 030350-00-0402 - Liquid applied roof waterproofing kits
- EAD 220069-00-0402 - Flat and profiled plastic roofing sheets made of recycled material for fully supported discontinuous roofing
- EAD 030218-01-0402 - Membranes for roof or wall underlays or both
- EN 13859-1 - Flexible sheets for waterproofing - underlays for discontinuous roofing
- EN 13967 - Flexible sheets for waterproofing - plastic and rubber damp proof sheets including basement tanking
- EN 13969 - Flexible sheets for waterproofing - bitumen damp proof sheets including basement tanking
- EN 15814 - Polymer modified bituminous thick coatings for waterproofing - definitions and requirements
- EN 15813 - Polymer modified bituminous thick coatings - flexibility at low temperatures