Harmonised or product standard

    EN 13859-2 - Flexible sheets for waterproofing - underlays for walls

    Testing · NAC-037-TL

    In short

    EN 13859-2 - Flexible sheets for waterproofing - underlays for walls. For wall underlays / breather membranes, Amstelfy covers watertightness, tensile and tear, vapour resistance and ageing in its ISO/IEC 17025-accredited laboratory (NAC-037-TL). Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 13859-2 is the harmonised product standard for flexible underlays fixed on the outside of a wall and covered by a cladding: the breather membranes of timber-frame and masonry-cavity walls. The membrane has two jobs, to drain water that gets past the cladding and to let vapour out of the wall, so the standard pairs a water penetration class with a declared sd value. Around these it adds tensile strength and elongation, nail-shank tear resistance, cold flexibility, dimensional stability, straightness, mass per unit area and reaction to fire, and requires water penetration and tensile strength to be repeated after an ageing sequence of UV and heat. The standard assumes the membrane is covered; permanently UV-exposed use behind open-jointed cladding is outside it. Conformity rests on type testing plus factory production control and ends in a Declaration of Performance.

    Type testing and factory production control

    Specimens come from one roll in both directions. The water penetration test applies a small head of water to the upper face and looks for passage to the underside; the vapour test seals the membrane over a cup and follows the mass change until it is steady, giving the sd value. Strip specimens are pulled to failure for strength and elongation and pierced with a nail for tear resistance; a strip is bent at low temperature. Ageing exposes a second set of specimens to UV radiation and water and then to heat, after which penetration and tensile tests are repeated. Reaction to fire goes through the European classification. Factory production control repeats the roll checks and key tests.

    What the report states

    The report gives the water penetration class before and after ageing, the sd value in metres, maximum tensile force in N per 50 mm and elongation in per cent for both directions, nail tear force in N, the cold-bend result, dimensional stability and the fire class. Each declared characteristic is written as the manufacturer's declared value with the tolerance the standard permits, ready for the Declaration of Performance.

    Where the result is required

    EN 13859-2 is the CE-marking standard for breather membranes and wall underlays in the EU and EEA. Timber-frame manufacturers, facade contractors and cladding system suppliers specify by its declared values: a low sd value for vapour-open walls, W1 for exposed sites, high nail tear for membranes stapled to studs. Membranes for open-jointed rainscreens, which need permanent UV resistance, are assessed under an EAD instead, and the same test data forms the starting point.

    What we assess

    • watertightness
    • tensile and tear
    • vapour resistance
    • ageing

    Products covered

    • wall underlays / breather membranes

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    The sd value is the thickness of still air with the same vapour resistance as the membrane. A low value lets moisture from the wall escape outwards so that the timber or insulation stays dry; a high value would trap it. The standard sets no limit, so the designer compares the declared sd with that of the inner vapour control layer.

    Only where the product, the test methods and the conditioning are identical, which is the case for most characteristics. The water penetration and tensile tests after ageing still need to be reported under Part 2, and the declaration must name Part 2 for wall use. One combined test programme is the usual approach for a membrane sold for both applications.

    EN 13859-2 assumes the membrane is shielded by a closed cladding after installation. Behind open joints it sees UV and rain for the life of the building, which the ageing in the standard does not represent. Such membranes are assessed under an EAD with longer UV exposure and declared under an ETA rather than under this standard.

    Related standards

    All Waterproofing membranes, roof underlays & liquid-applied systems testing