Harmonised or product standard

    EN 13969 - Flexible sheets for waterproofing - bitumen damp proof sheets including basement tanking

    Testing · NAC-037-TL

    In short

    EN 13969 - Flexible sheets for waterproofing - bitumen damp proof sheets including basement tanking. For bitumen damp proof membranes, Amstelfy covers watertightness, tensile and tear, flexibility at low temperature and durability in its ISO/IEC 17025-accredited laboratory (NAC-037-TL). Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 13969 is the harmonised product standard for bitumen sheets used as damp proof courses and membranes in walls and floors and as tanking of basement structures. Like its plastics counterpart it separates Type A, for damp proofing without a water head, from Type T, for tanking against water under pressure, with a higher watertightness level for Type T. Because bitumen is thermoplastic, the characteristics include flexibility at low temperature and the retention of that flexibility and of watertightness after heat ageing, in addition to watertightness, tensile strength and elongation, nail-shank tear resistance, joint strength in shear, resistance to impact and static loading, water vapour transmission and reaction to fire. Durability against chemicals in the ground is added where claimed. Type testing and factory production control support the Declaration of Performance and CE marking.

    Type testing and factory production control

    Specimens are cut in both directions from rolls of normal production; joint specimens are torch-bonded, hot-bitumen bonded or self-adhered as the manufacturer prescribes. Watertightness is tested by EN 1928 at the pressure for the declared type, tensile properties by EN 12311-1, nail tear by EN 12310-1, joint shear by EN 12317-1, impact by EN 12691, static loading by EN 12730 and cold flexibility by EN 1109. For durability, specimens are stored at elevated temperature to EN 1296 and then re-tested for flexibility and watertightness, and where chemical durability is declared they are immersed to EN 1847 before watertightness is repeated. Factory production control covers dimensions, thickness, mass per unit area, visible defects and periodic performance checks.

    What the report states

    The report gives watertightness as pass or fail at the test pressure, maximum tensile force (N/50 mm) and elongation (%), nail tear force (N), joint shear force (N/50 mm), impact and static-load results, the cold-bend temperature before and after heat ageing, the sd value and the fire class, plus thickness or mass per unit area and dimensions. These are the declared characteristics of the Declaration of Performance.

    Where the result is required

    EN 13969 is the CE-marking standard for SBS- and APP-modified bitumen damp proof courses, under-slab membranes, self-adhesive tanking sheets and torch-on tanking membranes for basements and retaining walls. Designers choose by type (A or T), cold-bend temperature for winter laying and the retained flexibility after ageing. Plastic and rubber damp proof sheets have their own standard, EN 13967, and liquid-applied basement waterproofing with bitumen emulsions uses EN 15814.

    What we assess

    • watertightness
    • tensile and tear
    • flexibility at low temperature
    • durability

    Products covered

    • bitumen damp proof membranes

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    The membrane is handled, unrolled and bonded on site, often in winter, and bitumen stiffens and cracks when cold. EN 1109 gives the lowest temperature at which a strip bends around a mandrel without cracking; after heat ageing to EN 1296 the test is repeated, because oxidised bitumen loses flexibility first. The retained value is declared.

    Rolls of each product variant from one production run, the carrier and surfacing details, and the bonding method for joints so that joint specimens can be prepared the way they are made on site. Self-adhesive products need the primer and release liner included; torch-on products need the torching instructions of the manufacturer.

    The test methods are shared with the roofing standard EN 13707, but the characteristic set here is chosen for ground contact: watertightness at the type pressure, impact and static loading from fill, chemical durability and heat ageing. A sheet sold for both roofing and tanking is tested and declared under both standards.

    Related standards

    All Waterproofing membranes, roof underlays & liquid-applied systems testing