EN 13969 - Flexible sheets for waterproofing - bitumen damp proof sheets including basement tanking
In short
EN 13969 - Flexible sheets for waterproofing - bitumen damp proof sheets including basement tanking. For bitumen damp proof membranes, Amstelfy covers watertightness, tensile and tear, flexibility at low temperature and durability in its ISO/IEC 17025-accredited laboratory (NAC-037-TL). Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.
What the standard covers
EN 13969 is the harmonised product standard for bitumen sheets used as damp proof courses and membranes in walls and floors and as tanking of basement structures. Like its plastics counterpart it separates Type A, for damp proofing without a water head, from Type T, for tanking against water under pressure, with a higher watertightness level for Type T. Because bitumen is thermoplastic, the characteristics include flexibility at low temperature and the retention of that flexibility and of watertightness after heat ageing, in addition to watertightness, tensile strength and elongation, nail-shank tear resistance, joint strength in shear, resistance to impact and static loading, water vapour transmission and reaction to fire. Durability against chemicals in the ground is added where claimed. Type testing and factory production control support the Declaration of Performance and CE marking.
Type testing and factory production control
Specimens are cut in both directions from rolls of normal production; joint specimens are torch-bonded, hot-bitumen bonded or self-adhered as the manufacturer prescribes. Watertightness is tested by EN 1928 at the pressure for the declared type, tensile properties by EN 12311-1, nail tear by EN 12310-1, joint shear by EN 12317-1, impact by EN 12691, static loading by EN 12730 and cold flexibility by EN 1109. For durability, specimens are stored at elevated temperature to EN 1296 and then re-tested for flexibility and watertightness, and where chemical durability is declared they are immersed to EN 1847 before watertightness is repeated. Factory production control covers dimensions, thickness, mass per unit area, visible defects and periodic performance checks.
What the report states
The report gives watertightness as pass or fail at the test pressure, maximum tensile force (N/50 mm) and elongation (%), nail tear force (N), joint shear force (N/50 mm), impact and static-load results, the cold-bend temperature before and after heat ageing, the sd value and the fire class, plus thickness or mass per unit area and dimensions. These are the declared characteristics of the Declaration of Performance.
Where the result is required
EN 13969 is the CE-marking standard for SBS- and APP-modified bitumen damp proof courses, under-slab membranes, self-adhesive tanking sheets and torch-on tanking membranes for basements and retaining walls. Designers choose by type (A or T), cold-bend temperature for winter laying and the retained flexibility after ageing. Plastic and rubber damp proof sheets have their own standard, EN 13967, and liquid-applied basement waterproofing with bitumen emulsions uses EN 15814.
What we assess
- watertightness
- tensile and tear
- flexibility at low temperature
- durability
Products covered
- bitumen damp proof membranes
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | No |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EAD 030350-00-0402 - Liquid applied roof waterproofing kits
- EAD 220069-00-0402 - Flat and profiled plastic roofing sheets made of recycled material for fully supported discontinuous roofing
- EAD 030218-01-0402 - Membranes for roof or wall underlays or both
- EN 13859-1 - Flexible sheets for waterproofing - underlays for discontinuous roofing
- EN 13859-2 - Flexible sheets for waterproofing - underlays for walls
- EN 13967 - Flexible sheets for waterproofing - plastic and rubber damp proof sheets including basement tanking
- EN 15814 - Polymer modified bituminous thick coatings for waterproofing - definitions and requirements
- EN 15813 - Polymer modified bituminous thick coatings - flexibility at low temperatures