Harmonised or product standard

    EN 13859-1 - Flexible sheets for waterproofing - underlays for discontinuous roofing

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 13859-1 - Flexible sheets for waterproofing - underlays for discontinuous roofing. For roof underlays, Amstelfy covers watertightness (W1-W3), tensile and tear, water vapour resistance and flexibility at low temperature in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 13859-1 is the harmonised product standard for flexible underlays laid beneath discontinuous roof coverings, whether bitumen, plastic, rubber or multilayer spun-bonded membranes. It defines the characteristics a manufacturer declares and the test methods for each: resistance to water penetration in classes W1 to W3, tensile strength and elongation, resistance to tearing at the nail shank, water vapour transmission as an sd value, flexibility at low temperature, dimensional stability, straightness, mass per unit area and reaction to fire, together with the same properties after artificial ageing. The ageing procedure in the standard combines a UV exposure representing the period before the roof covering is laid with a long heat storage. Conformity is shown by initial type testing of each characteristic and continuous factory production control, which together support the Declaration of Performance and CE marking.

    Type testing and factory production control

    A type-testing programme takes specimens from one roll in both directions. Water penetration for class W1 is checked under a low hydrostatic head adapted from EN 1928 method A, tensile properties by EN 12311-1 or EN 12311-2, nail tear by EN 12310-1, water vapour transmission by the cup method and cold flexibility by EN 1109 for bitumen or EN 495-5 for plastics and rubber. A second set of specimens is aged by UV followed by heat as the standard prescribes and re-tested for water penetration and tensile strength. Reaction to fire is classified under EN 13501-1. Factory production control then covers raw materials, mass per unit area, dimensions, visible defects and periodic repeats of the key tests.

    What the report states

    For each characteristic the report gives the measured values in both directions and the class or declared value that follows: W class before and after the ageing sequence, tensile force (N/50 mm) and elongation (%), nail tear (N), sd (m), the lowest temperature at which the sheet bends without cracking, dimensional change (%) and the reaction-to-fire class. The manufacturer copies these into the Declaration of Performance under the AVCP system that Annex ZA assigns.

    Where the result is required

    Required for CE marking of every roof underlay sold in the EU and EEA, from lightweight spun-bonded breather membranes to heavy bitumen sarking felts and underlays with integrated adhesive laps. National application documents and roofing guides use the W class, the sd value and the tensile and tear values to decide whether an underlay is suitable for a given pitch, exposure or ventilated versus unventilated roof build-up, so the declared values also drive specification.

    What we assess

    • watertightness (W1-W3)
    • tensile and tear
    • water vapour resistance
    • flexibility at low temperature
    • ageing

    Products covered

    • roof underlays

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    Part 1 covers underlays beneath discontinuous roof coverings; Part 2 covers underlays behind external wall claddings. The characteristics and methods overlap to a large extent, but the roof part addresses the sloped, nailed and temporarily exposed situation, while the wall part addresses vertical drainage behind cladding. A membrane sold for both uses is tested and declared under both.

    W1 is the class most roofing guides expect for underlays that may carry wind-driven rain or snow for a time; it is shown by withstanding the low hydrostatic head in the standard both before and after ageing. W2 is a lower performance level and W3 means neither level is met. The class after ageing is what counts for the declaration.

    The sequence combines a UV exposure measured in weeks with a heat storage measured in months, so the aged results arrive long after the unaged ones. Programmes therefore start with the ageing exposure first and run the unaged tests in parallel, so that the full type-testing report is complete when the aged specimens come out.

    Related standards

    All Waterproofing membranes, roof underlays & liquid-applied systems testing