European Assessment Document
EAD 030218-01-0402 - Membranes for roof or wall underlays or both
In short
EAD 030218-01-0402 is the EOTA European Assessment Document for membranes for roof or wall underlays or both. Amstelfy Technical Solutions tests breather membranes and underlays against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): water vapour transmission, watertightness, tensile and tear resistance and UV and heat ageing. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.
What the EAD assesses
EAD 030218-01-0402 is the assessment document for membranes used as underlays beneath discontinuous roof coverings, behind wall claddings, or in both positions, where the product or its intended use is not covered by the harmonised standards EN 13859-1 and EN 13859-2. Typical cases are membranes with an extended exposure period before the covering is fitted, use behind open-jointed claddings where UV reaches the membrane for the life of the building, airtightness functions, or composite products with integrated tapes and self-adhesive zones. The EAD defines the essential characteristics, mainly resistance to water penetration, water vapour transmission expressed as an sd value, tensile strength and elongation, resistance to tearing at nails, reaction to fire and the durability of these properties after artificial ageing, and lets the manufacturer choose which of them are assessed.
Assessment programme
Specimens are cut from rolls of normal production in both directions. Reference tests use the methods of the sheet-membrane series: water penetration under a low hydrostatic head, water vapour transmission by the cup method, tensile strength and elongation on strip specimens, and nail-shank tear. The durability part is the core of the assessment: specimens are exposed to UV radiation with water and then to heat for periods that match the claimed exposure class, and the water-penetration and tensile tests are repeated. Where the membrane is meant for open-jointed cladding, the UV exposure is longer than the construction-period exposure of EN 13859. Reaction to fire follows the European classification; air permeability or tape adhesion is tested only where claimed.
What the report states
The report lists each characteristic as measured, before and after ageing: water penetration class, sd value in metres, tensile force in N per 50 mm width and elongation in per cent, nail tear force in N and fire class. Retained percentages after ageing show whether the claimed exposure period is justified. The Technical Assessment Body writes these into the ETA and the manufacturer declares them in the Declaration of Performance.
Where the result is required
Manufacturers use this EAD when a roof or wall underlay cannot be CE marked under EN 13859-1 or EN 13859-2, most often UV-stable facade membranes for open-jointed rainscreen cladding, sarking membranes with long declared exposure times, and membranes with integrated adhesive edges. The test methods are the same ones cited by the two harmonised standards, so a manufacturer already producing standard underlays extends an existing data set rather than starting again.
What we assess
- water vapour transmission
- watertightness
- tensile and tear resistance
- UV and heat ageing
Products covered
- breather membranes
- underlays
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | Yes |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EAD 030350-00-0402 - Liquid applied roof waterproofing kits
- EAD 220069-00-0402 - Flat and profiled plastic roofing sheets made of recycled material for fully supported discontinuous roofing
- EN 13859-1 - Flexible sheets for waterproofing - underlays for discontinuous roofing
- EN 13859-2 - Flexible sheets for waterproofing - underlays for walls
- EN 13967 - Flexible sheets for waterproofing - plastic and rubber damp proof sheets including basement tanking
- EN 13969 - Flexible sheets for waterproofing - bitumen damp proof sheets including basement tanking
- EN 15814 - Polymer modified bituminous thick coatings for waterproofing - definitions and requirements
- EN 15813 - Polymer modified bituminous thick coatings - flexibility at low temperatures