    EN 13967 - Flexible sheets for waterproofing - plastic and rubber damp proof sheets including basement tanking. For plastic and rubber damp proof membranes, Amstelfy covers watertightness, tensile properties, resistance to impact and static loading and joint strength in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 13967 is the harmonised product standard for plastic and rubber sheets that keep ground moisture and ground water out of buildings: damp proof courses and membranes, and tanking membranes applied to basement structures. It distinguishes Type A sheets, which stop moisture and damp without a water head, from Type T sheets intended for tanking against water under pressure, for which the watertightness requirement is more severe. The characteristics are those that decide whether a buried membrane stays tight: watertightness, resistance to impact and to static loading from fill and aggregate, tensile properties, tear resistance, joint strength in shear, water vapour transmission, and durability of watertightness after heat ageing and after exposure to chemicals including alkaline ground water. Type testing of these characteristics plus factory production control support the Declaration of Performance.

    Type testing and factory production control

    Specimens are cut from production rolls in both directions, and joint specimens are made by the welding or taping method of the manufacturer. Watertightness uses EN 1928 at the pressure the standard assigns to Type A or Type T, impact resistance EN 12691, static loading EN 12730, tensile properties EN 12311-2, nail tear EN 12310-1, joint shear EN 12317-2 and water vapour transmission EN 1931. For durability, sets of specimens are heat aged to EN 1296 and immersed in liquids to EN 1847 before the watertightness test is repeated; contact with bitumen is checked by EN 1548 where the sheet may touch bituminous materials. Factory production control monitors dimensions, thickness, mass per unit area and the key performance tests.

    What the report states

    The report states the type and the pass or fail watertightness result, impact resistance as the greatest drop height without leakage, static load as the greatest mass carried, tensile force in N per 50 mm or strength in N/mm² with elongation, tear and joint forces in N, the sd value, and the watertightness after ageing and after chemical exposure. The manufacturer declares these together with thickness and mass per unit area in the Declaration of Performance.

    Where the result is required

    EN 13967 is the CE-marking route for polyethylene, PVC, EPDM and TPO damp proof membranes, gas-resistant DPMs declared as damp proofing, and tanking membranes for basements. Specifiers use the type (A or T), the impact and static-load results and the chemical durability to choose membranes for ground-bearing slabs, retaining walls and below-grade car parks. The bitumen equivalent is EN 13969, which uses the Part 1 test methods of the same series.

    What we assess

    • watertightness
    • tensile properties
    • resistance to impact and static loading
    • joint strength
    • durability

    Products covered

    • plastic and rubber damp proof membranes

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    Type A sheets protect against ground moisture and water that is not under pressure, such as a damp proof course or a membrane under a slab on a drained base. Type T sheets are for tanking, where ground water may stand against the structure, so the watertightness test pressure and the durability requirements are higher. The type is declared on the CE label.

    Joint specimens are made the way the installer would make them on site, by hot-air or wedge welding, solvent welding or with the tape of the manufacturer, and pulled in shear to EN 12317-2. The report gives the force at failure and whether the joint or the sheet broke; a joint stronger than the sheet is the usual target.

    Buried membranes sit against fresh concrete, which is strongly alkaline, and in some ground against acids, salts or hydrocarbons. EN 1847 immerses specimens in the chosen liquids, after which watertightness is re-tested; this shows whether plasticiser loss, swelling or embrittlement would open the membrane during its service life.

    Related standards