Test method

    EN 1847 - Flexible sheets for waterproofing - exposure to liquid chemicals including water

    Testing · NAC-037-TL

    In short

    EN 1847 - Flexible sheets for waterproofing - exposure to liquid chemicals including water. Amstelfy's laboratory determines chemical resistance of plastic and rubber sheets according to EN 1847 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN 1847 determines

    EN 1847 provides the procedures for exposing plastic and rubber waterproofing sheets to liquid chemicals, including water, so that the effect of the liquid on the sheet can be measured afterwards. Membranes in the ground meet alkaline water from fresh concrete, acids and sulphates in some soils, de-icing salts, fertilisers on green roofs; even plain water at elevated temperature extracts plasticisers and stabilisers from some polymers. The standard defines how specimens are immersed, at which temperatures and for which periods, and leaves the choice of liquid and the subsequent property test to the product standard or the client. Typical follow-up tests are change in mass and dimensions, tensile properties to EN 12311-2 and watertightness to EN 1928. The result is therefore always a comparison between exposed and unexposed specimens, and it underpins the durability-against-chemicals characteristic in product declarations.

    Specimens, conditioning and procedure

    Specimens are prepared for the property tests that will follow, measured, weighed and labelled, with an unexposed reference set kept in the standard climate. The chosen liquids are prepared to the concentrations specified, for example saturated calcium hydroxide solution for alkaline exposure, and placed in closed containers. The specimens are fully immersed, separated from each other so the liquid reaches all faces, and stored at the temperature and for the period the standard or the product standard specifies, with the liquid renewed where required. After exposure the specimens are rinsed, surface-dried and conditioned, then weighed and measured again and submitted to the property tests. Changes in mass, dimensions, strength, elongation or watertightness are calculated relative to the references.

    What the report states

    The report lists each liquid with concentration, temperature and immersion period, and for each the change in mass and dimensions in per cent, the retained tensile force or strength and elongation, the result of the watertightness test after exposure and any visible change such as swelling, discolouration or surface cracking. Product standards set permitted changes; the manufacturer declares durability against chemicals as pass or fail for the liquids tested.

    Where the result is required

    Cited by EN 13967 for plastic and rubber damp proof and tanking sheets, whose watertightness must be shown after chemical exposure, and by EN 13956 for roofing sheets where resistance to specific liquids is claimed; its bitumen counterpart EN 13969 asks for the same characteristic. Also used for geomembranes, pond liners and secondary containment membranes against project-specific liquids, and by manufacturers to qualify a formulation change in plasticiser or stabiliser before a full type-testing programme.

    What we assess

    • chemical resistance

    Products covered

    • plastic and rubber sheets

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Those the product standard requires plus those relevant to the intended use. For buried membranes the alkaline exposure representing fresh concrete is the usual minimum; tanking sheets near roads add de-icing salt solutions, green-roof membranes add fertiliser solutions, and containment membranes add the stored chemical. Each liquid is a separate exposure with its own specimens and reference set.

    The standard sets the period and temperature for the standard exposures, and the product standard may extend them; project-specific exposures follow the specification of the client. Elevated temperature accelerates uptake and extraction, so the temperature is stated with every result. Because the property tests follow the immersion, the exposure is started at the beginning of the programme.

    For damp proof and tanking sheets, watertightness to EN 1928 after exposure is the declared characteristic. Change in mass shows whether the sheet absorbs liquid or loses plasticiser, and the retained tensile properties show embrittlement or softening. The combination of the three, reported against unexposed references, tells the manufacturer what the liquid does to the polymer.

    Related standards