Test method

    ISO 1817 - Rubber, vulcanized or thermoplastic - effect of liquids

    Testing · NAC-037-TL

    In short

    ISO 1817 - Rubber, vulcanized or thermoplastic - effect of liquids. Amstelfy's laboratory determines swelling / effect of liquids of rubber compounds, elastomeric bearings and seals and waterstops according to ISO 1817 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What ISO 1817 determines

    ISO 1817 describes how to measure what happens to a vulcanised or thermoplastic rubber when it is immersed in a liquid. Test pieces are exposed to the liquid at a set temperature for a set time and the changes in mass, volume, dimensions, hardness and tensile properties are measured; the extractable matter can also be determined by drying. Swelling indicates absorption of the liquid, shrinkage indicates extraction of plasticiser, and changes in hardness and tensile properties show whether the compound still functions. The standard defines reference liquids, the IRM 901, 902 and 903 oils and fuel-like mixtures of isooctane and toluene, so that resistance can be ranked on a common basis, and it allows any service liquid such as water, hydraulic fluid or a de-icing solution to be used instead.

    Specimens, conditioning and procedure

    Test pieces are cut from sheet or from the product: rectangular pieces for mass and volume change, ISO 37 dumb-bells for tensile properties after immersion, and hardness pieces as needed. The pieces are fully immersed in the chosen liquid in a closed vessel, separated from each other, with the volume of liquid the standard requires relative to the rubber, and held in an oven or bath at the chosen temperature and duration from the preferred series. After removal they are cooled in fresh liquid where applicable, blotted and re-weighed within the time limit, then re-measured. The client specifies the liquid, temperature and time, and whether properties are to be tested wet or after drying.

    What the report states

    Changes in mass and volume are reported as percentages of the initial values, dimensional changes as percentages per direction, hardness change in IRHD or Shore units and tensile changes as percentages of the unaged medians, each with the liquid, temperature and duration. Where extractable matter is determined it is given as a percentage of the initial mass. Product standards set limits, for example on volume change of seals in oil or water.

    Where the result is required

    ISO 1817 supplies the liquid-resistance characteristics in standards for pipe and tunnel seals in contact with water, oil and sewage (EN 681-1 and related parts), for bearings exposed to oils and fuels, for waterstops in contact with bitumen, groundwater or chemicals, and for hoses and gaskets in machinery. It also supports chemical-resistance tables on data sheets and the durability assessment of elastomeric components in ETA programmes.

    What we assess

    • swelling / effect of liquids

    Products covered

    • rubber compounds
    • elastomeric bearings and seals
    • waterstops

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    The standard defines reference liquids: the IRM 901, 902 and 903 oils of increasing swelling power and fuel-like mixtures of isooctane and toluene, plus distilled water. Any service liquid can be substituted when the client's application requires it, for example a hydraulic fluid, a cleaning agent or sea water; the report then identifies the liquid by trade name or composition.

    Mass change records the net effect of absorbed liquid and extracted ingredients. Volume change, obtained by weighing in air and in water before and after immersion, measures swelling directly and is the figure most specifications limit because it governs whether a seal still fits. A compound can show small mass change but significant swelling when extraction and absorption offset.

    Duration is chosen from the standard's preferred series, typically 24, 72 or 168 hours, by the product standard or the client. Send moulded sheet about 2 mm thick, or product pieces large enough for the immersion and tensile test pieces, from one batch. Material for reference measurements before immersion comes from the same sheet.

    Related standards

    All Rubber, elastomers, sealants & adhesives testing