Test method
EN 15817 - Polymer modified bituminous thick coatings - water resistance
In short
EN 15817 - Polymer modified bituminous thick coatings - water resistance. Amstelfy's laboratory determines water resistance of PMBC coatings according to EN 15817 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.
What EN 15817 determines
EN 15817 determines the water resistance of a polymer modified bituminous thick coating once it has fully dried: whether a film that will spend decades against damp soil tolerates permanent contact with water without swelling, softening, blistering or losing adhesion to its substrate. Bitumen itself is water-resistant; the risk lies in the emulsifiers, fillers and polymer dispersions that remain in the dried film and can take up water again. The method stores coated specimens under water for the period the standard specifies and then assesses the film and the water. It is a durability screening test rather than a measurement of permeability, which is covered by the watertightness test EN 15820. A coating that passes keeps its integrity so that the crack-bridging and watertightness classes remain valid in service.
Specimens, conditioning and procedure
The coating is applied to the substrate specified in the standard at the declared dry film thickness and cured under laboratory climate until fully dry. The specimens are then immersed in water at the temperature and for the period given in the standard. At the end of storage they are taken out, surface water is removed and the film is examined for blisters, swelling, softening when pressed, cracks and detachment at the edges and at the substrate; the water is inspected for discolouration and dissolved or detached material. Where the client wishes, mass before and after immersion is recorded to quantify water uptake, and a crack-bridging or adhesion test can follow on the same specimens.
What the report states
The report describes the condition of the coating after water storage against the acceptance criteria of EN 15814 and states pass or fail, with photographs of the surface and edges, the storage temperature and period, and the water uptake if measured. The result supports the water resistance line of the Declaration of Performance and documents that the tested build-up is suitable for permanent ground contact.
Where the result is required
A required characteristic of EN 15814 for CE marking of bitumen thick coatings used on basement walls, foundations and plinths, and a routine development test when emulsifier systems, fillers or polymer dispersions are changed. It is also used as a pre-conditioning step when a client wants crack bridging or adhesion determined on water-aged specimens, and to compare the moisture sensitivity of formulations before a full EN 15814 programme is started.
What we assess
- water resistance
Products covered
- PMBC coatings
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | No |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EAD 030350-00-0402 - Liquid applied roof waterproofing kits
- EAD 220069-00-0402 - Flat and profiled plastic roofing sheets made of recycled material for fully supported discontinuous roofing
- EAD 030218-01-0402 - Membranes for roof or wall underlays or both
- EN 13859-1 - Flexible sheets for waterproofing - underlays for discontinuous roofing
- EN 13859-2 - Flexible sheets for waterproofing - underlays for walls
- EN 13967 - Flexible sheets for waterproofing - plastic and rubber damp proof sheets including basement tanking
- EN 13969 - Flexible sheets for waterproofing - bitumen damp proof sheets including basement tanking
- EN 15814 - Polymer modified bituminous thick coatings for waterproofing - definitions and requirements