Test method

    EN 15816 - Polymer modified bituminous thick coatings - resistance to rain

    Testing · NAC-037-TL

    In short

    EN 15816 - Polymer modified bituminous thick coatings - resistance to rain. Amstelfy's laboratory determines resistance to rain of PMBC coatings according to EN 15816 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN 15816 determines

    EN 15816 determines the resistance to rain of a polymer modified bituminous thick coating during the drying phase, the period when a bitumen emulsion is most vulnerable: until the emulsion has broken and the film has formed, water can re-emulsify the surface and wash it off a basement wall. The method applies the coating at its declared thickness, lets it dry for the time after which the manufacturer claims it is rain-resistant, and then exposes it to simulated rain. Damage, run-off of material and discolouration of the water show that the claimed time is too short. The result confirms the rain-resistance time the manufacturer prints in the application instructions, which installers use to decide whether a coating can be left uncovered overnight.

    Specimens, conditioning and procedure

    The coating is applied to a vertical or inclined substrate at the declared wet thickness under standard laboratory climate and left to dry for the rain-resistance time the manufacturer declares. The specimen is then exposed to a water spray of the intensity and duration specified in the standard, arranged to simulate rain falling on the coating. During and after the exposure the surface is observed for washing-out, blistering, cracking and delamination, and the run-off water is checked for bitumen. Where the client wants to establish the shortest defensible time, several specimens are exposed after different drying periods, each reported separately. Temperature and humidity during drying are recorded because they govern how fast the emulsion breaks.

    What the report states

    The report states the drying time before exposure, the spray conditions and whether the coating survived without damage or loss of material; the rain-resistance time declared in the Declaration of Performance is the drying time at which the coating passed. Observations are supported by photographs of the surface and of the collected run-off water.

    Where the result is required

    One of the characteristics of EN 15814 for CE marking of PMBC products and the technical basis for the rain-resistance time on product data sheets. Manufacturers run it when reformulating emulsifiers or fillers, because small changes shift the film-forming time, and when extending a product to cooler or more humid application conditions. It applies only to thick coatings; sheet membranes have no equivalent because they are factory-made.

    What we assess

    • resistance to rain

    Products covered

    • PMBC coatings

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    The standard fixes the climate for drying and exposure so that results from different laboratories agree. A manufacturer who wants to know the behaviour at a lower temperature can commission additional specimens dried under that climate, reported as a supplementary test outside the standard conditions, but the declared rain-resistance time comes from the standard climate.

    Visible washing-out of the coating, bitumen in the run-off water, blisters, cracks or detachment from the substrate after the spray. A slight change of surface sheen without loss of material is not a failure. The report describes the observed condition so the manufacturer can judge how much margin the declared time has.

    Product from one batch, the primer if the system uses one, the declared wet thickness per coat, the claimed rain-resistance time and the standard substrate preparation. Two-component products also need the mixing ratio and pot life. Specimens are prepared in the laboratory to keep thickness and timing under control.

    Related standards

    All Waterproofing membranes, roof underlays & liquid-applied systems testing