Test method

    EN 12730 - Flexible sheets for waterproofing - resistance to static loading

    Testing · NAC-037-TL

    In short

    EN 12730 - Flexible sheets for waterproofing - resistance to static loading. Amstelfy's laboratory determines resistance to static loading of bitumen, plastic and rubber sheets according to EN 12730 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN 12730 determines

    EN 12730 determines the resistance of flexible waterproofing sheets to static loading: the ability to carry a concentrated, sustained point load without being perforated, the situation under a paving support, a piece of gravel pressed by foot traffic or an unevenness in the substrate. A steel ball of 10 mm diameter is pressed into the specimen by a dead load for 24 h, after which the sheet is checked for perforation. The load is raised in steps with fresh specimens, and the largest load the sheet carries without perforation, expressed in kilograms, is the result. As with the impact test, two support conditions are used, a rigid and a compressible substrate, because a sheet on concrete is sheared against the ball while a sheet on insulation is stretched over it. The method applies to bitumen, plastic and rubber sheets alike.

    Specimens, conditioning and procedure

    Specimens are conditioned in the standard laboratory climate and placed, surfacing up, on the substrate of the method in use, a rigid plate or a compressible board. The 10 mm steel ball is set on the specimen and the loading device is applied so that the chosen mass acts through the ball for 24 h. The specimen is then released and examined for a hole or crack through its full thickness at the loading point, normally by a watertightness check with a liquid indicator. The procedure is repeated on new specimens at the next load step until perforation occurs. The result is the largest load at which no specimen was perforated; both substrates are tested where the product standard requires.

    What the report states

    The report states the resistance to static loading as the largest mass in kg without perforation, separately for the rigid-substrate and the soft-substrate method, with the test temperature, duration, substrate and the method used to check perforation. Product standards have the manufacturer declare the value in the Declaration of Performance, and roofing guides set minimum values for membranes under paving or ballast.

    Where the result is required

    Cited by EN 13707 and EN 13956 for roofing sheets, by EN 13967 and EN 13969 for damp proof and tanking sheets exposed to fill and point loads from protection boards. Specifiers of inverted roofs, paved terraces and green roofs use it to decide whether a protection layer is needed between membrane and ballast. For liquid-applied kits the equivalent is static indentation under EAD 030350-00-0402.

    What we assess

    • resistance to static loading

    Products covered

    • bitumen, plastic and rubber sheets

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Impact is a short, dynamic event that punches or tears the sheet; static loading is a slow, sustained pressure that lets the bitumen or polymer creep around the ball. Thick, soft compounds absorb impact well but may creep through under sustained load, so a sheet can rank high in one test and low in the other. The two are declared separately.

    Creep of the membrane and of a compressible substrate takes time: a load that is harmless after a minute can perforate after a day as the material thins under the ball. The 24 h period in the standard captures this and makes the result reproducible between laboratories, while remaining practical for a stepwise test series.

    It tells them whether a membrane can take paving pedestals, gravel or planters directly or needs a protection fleece or board. A high rigid-substrate value suits membranes bonded to concrete under paving; a high soft-substrate value suits membranes over insulation on inverted roofs. The declared load is compared with the point loads expected from the roof build-up.

    Related standards