Test method
EN 1109 - Flexible sheets for waterproofing - flexibility at low temperature - bitumen sheets
In short
EN 1109 - Flexible sheets for waterproofing - flexibility at low temperature - bitumen sheets. Amstelfy's laboratory determines flexibility at low temperature of bitumen sheets according to EN 1109 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.
What EN 1109 determines
EN 1109 determines the flexibility at low temperature of bitumen waterproofing sheets, the cold-bend temperature. Bitumen passes from a viscoelastic to a brittle state as it cools, and the temperature at which this happens depends on the base bitumen and on the polymer modification: SBS-modified sheets stay flexible far below zero, APP-modified sheets less so, oxidised bitumen least. A sheet unrolled or folded in winter must not crack. The method bends strip specimens through 180° around a mandrel while they are held at a controlled low temperature, examines them for cracks and repeats at lower temperatures until cracks appear. Both faces of the sheet are tested, because the coating on each side may differ. The result is a temperature in degrees Celsius, and the same test after heat ageing shows how fast the sheet loses flexibility with age.
Specimens, conditioning and procedure
Strip specimens are cut from the sheet, with any release film removed. They are conditioned at the first test temperature in a cooling bath or chamber for the period the standard specifies, then bent through 180° around a cylindrical mandrel of the diameter the standard fixes, at a constant speed, with the face under test on the outside of the bend. Immediately afterwards the bent zone is examined for cracks in the coating. The procedure is repeated with fresh specimens at temperatures stepped downwards in the increment the standard specifies until cracks occur in the coating, separately for the upper and the lower face. The number of specimens per temperature and face follows the standard.
What the report states
The report states the cold-bend temperature in °C for the upper and the lower face: the lowest temperature at which the required number of specimens showed no cracks, with the next lower temperature at which cracks appeared. The face that cracks first governs the declared value. Product standards require the manufacturer to declare the value, and after heat ageing to EN 1296 the shift in temperature is reported as well.
Where the result is required
Cited by EN 13707 for bitumen roofing sheets, EN 13969 for damp proofing and tanking, EN 13970 for vapour control layers, EN 14695 for bridge decks and EN 13859-1 and EN 13859-2 for bitumen underlays, in each case before and after artificial ageing. Specifiers in cold climates read the cold-bend temperature as the lowest temperature for installation, and manufacturers use it in factory production control as a routine check that the polymer modification of a batch is correct.
What we assess
- flexibility at low temperature
Products covered
- bitumen sheets
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | No |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EAD 030350-00-0402 - Liquid applied roof waterproofing kits
- EAD 220069-00-0402 - Flat and profiled plastic roofing sheets made of recycled material for fully supported discontinuous roofing
- EAD 030218-01-0402 - Membranes for roof or wall underlays or both
- EN 13859-1 - Flexible sheets for waterproofing - underlays for discontinuous roofing
- EN 13859-2 - Flexible sheets for waterproofing - underlays for walls
- EN 13967 - Flexible sheets for waterproofing - plastic and rubber damp proof sheets including basement tanking
- EN 13969 - Flexible sheets for waterproofing - bitumen damp proof sheets including basement tanking
- EN 15814 - Polymer modified bituminous thick coatings for waterproofing - definitions and requirements