European Assessment Document
EAD 330387-00-0601 - Glass fibre-reinforced plastic (GFRP) connectors for use in sandwich and element walls made of concrete
In short
EAD 330387-00-0601 is the EOTA European Assessment Document for glass fibre-reinforced plastic (gfrp) connectors for use in sandwich and element walls made of concrete. Amstelfy Technical Solutions tests GFRP connectors for sandwich wall panels against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): tension and shear resistance, durability in alkaline environment and creep. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.
What the EAD assesses
EAD 330387-00-0601 assesses glass-fibre reinforced polymer connectors that join the facing layer of a concrete sandwich wall to its load-bearing layer through the insulation, or hold the two shells of a precast element wall together until the core is cast. The connectors replace stainless-steel ties to remove the thermal bridge, but a pultruded or moulded GFRP pin behaves differently from steel: its strength is direction-dependent, it does not yield, it loses strength under sustained load and it is attacked by the alkaline pore water of concrete. The EAD therefore assesses the characteristic resistance to tension and to shear for the connector anchored in both layers across the declared insulation thicknesses, the stiffness of the connection, long-term strength retention in alkaline environment, creep and creep rupture under sustained load, behaviour at the temperature limits and the anchorage detail in each layer.
Assessment programme
Connectors are cast into two-layer concrete specimens with the insulation and layer thicknesses to be claimed, so that the free length of the connector between the layers is representative. Tension tests pull the layers apart to fail the anchorage or the connector; shear tests displace one layer parallel to the other, which loads the connector in bending and shear across the gap, and record load against relative displacement. Durability specimens are stored in alkaline solution at elevated temperature for the periods set by the EAD and then tested in tension to establish the residual-strength curve; sustained-load tests at several stress levels give the creep-rupture relationship. Freeze-thaw cycling and tests at the temperature limits complete it.
What the report states
The report gives per connector type, insulation thickness and layer thickness the ultimate loads, failure modes (connector rupture, pull-out from a layer, concrete breakout), stiffness values and 5 % fractiles, together with the strength-retention factors from the alkaline and sustained-load series. The TAB combines these into characteristic short-term resistances, long-term reduction factors, connection stiffness and the geometric conditions stated in the ETA.
Where the result is required
Precast producers and structural engineers use the ETA to design the ties of sandwich panels for wind, the dead load of the facing layer, thermal bowing and handling, and the connectors of element walls for fresh-concrete pressure during casting, with the design method referenced in the ETA. Products are pultruded pins, grids and plate connectors of GFRP, CE marked under the AVCP system stated in the EAD. The material behaviour parallels FRP reinforcing bars assessed under EAD 260023, and the US route is ICC-ES AC320.
What we assess
- tension and shear resistance
- durability in alkaline environment
- creep
Products covered
- GFRP connectors for sandwich wall panels
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | Yes |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EAD 330232-00-0601 - Mechanical fasteners for use in concrete
- EAD 330499-00-0601 - Bonded fasteners for use in concrete
- EAD 330087-01-0601 - Systems for post-installed rebar connections with mortar
- EAD 330008-04-0601 - Anchor channels
- EAD 330011-00-0601 - Adjustable concrete screws
- EAD 330076-00-0604 - Metal injection anchors for use in masonry
- EAD 330083-02-0601 - Power-actuated fasteners for multiple use in concrete for non-structural applications
- EAD 330084-00-0601 - Steel plate with cast-in anchors