    EAD 330084-00-0601 is the EOTA European Assessment Document for steel plate with cast-in anchors. Amstelfy Technical Solutions tests embedded plates with headed studs or anchors against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): tension, shear and combined resistance, weld and anchor behaviour and durability. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.

    What the EAD assesses

    EAD 330084-00-0601 assesses prefabricated connection plates: a steel plate with headed studs, threaded anchors or reinforcing-bar anchors welded or screwed to its back, cast into in-situ or precast concrete so that steel members, brackets or other elements can be bolted or welded to the exposed face. The product is a single unit whose performance depends on plate thickness and yield strength, the weld between anchor and plate, the anchor head and shaft, and the concrete around them. The EAD therefore assesses resistance to tension, shear and combined loading for the steel modes (anchor shaft, weld, plate bending and punching) and confirms the concrete modes (cone, pull-out of the head, blow-out, pry-out, edge failure) that the ETA treats by calculation. Tolerances, anchor positions and corrosion protection of the exposed face are also assessed.

    Assessment programme

    Plates from production are cast into concrete members of the claimed strength at the specified embedment and edge positions, and loaded through a fixture that reproduces the intended attachment. Tension tests pull the plate normal to the concrete surface to fail the anchors, the welds or the plate; shear tests load parallel to the surface towards and away from an edge; combined series apply inclined loads. Component tests on the weld (tensile and bend tests on studs welded to plate coupons) and on the anchor steel accompany the full-size tests. Where the manufacturer claims it, series in cracked concrete, under repeated loading or on galvanised and stainless variants are added.

    What the report states

    The report gives per plate type and anchor layout the ultimate loads, displacements and governing failure mode for tension, shear and combined loading, the 5 % fractiles and the weld test outcomes. The TAB uses the steel results directly and the concrete-related results to confirm the design model, then states in the ETA the characteristic resistances, the embedment, spacing and edge conditions, the plate and anchor materials and the corrosion protection.

    Where the result is required

    Embedded plates connect steel beams, balcony and stair supports, facade brackets, lift and crane rails and precast elements to concrete; design follows EN 1992-4 for the headed fasteners together with the ETA values, and the product is CE marked under the AVCP system stated in the EAD. Plates that must accept adjustable positions along a line are usually replaced by anchor channels under EAD 330008; post-installed alternatives for the same loads are assessed under EAD 330232 or EAD 330499.

    What we assess

    • tension, shear and combined resistance
    • weld and anchor behaviour
    • durability

    Products covered

    • embedded plates with headed studs or anchors

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    No. ETAs are issued by Technical Assessment Bodies designated under the CPR. Amstelfy carries out the assessment tests in its accredited laboratory, prepares the test reports to the EAD's clause structure and coordinates the test plan with the TAB of your choice.

    The stud or anchor weld to the plate carries the full tension of the anchor, so the EAD requires evidence of the welding process and weld tests on specimens taken from production: tensile tests to fracture of stud-to-plate joints and bend tests that must not open the weld. The full-size tension tests then show whether the weld, the shaft or the plate governs.

    The ETA covers the plate sizes, thicknesses, anchor numbers and layouts that were tested or that fall within a range the TAB accepts by interpolation. Typically the smallest and largest plates and the thinnest plate with the widest anchor spacing are tested, since plate bending governs there. Each anchor type (headed stud, threaded anchor, rebar anchor) is a separate case.

    Concrete cone, head pull-out and edge failures are calculated with EN 1992-4 from the embedment depth and head dimensions, which is why the tests mainly confirm those models and measure the steel modes. The ETA states the minimum member thickness, edge distance and reinforcement conditions needed for the calculated values to apply.

    Related standards