European Assessment Document

    EAD 330011-00-0601 - Adjustable concrete screws

    Testing · NAC-037-TLCertification · NAC-026-PPSETA route

    In short

    EAD 330011-00-0601 is the EOTA European Assessment Document for adjustable concrete screws. Amstelfy Technical Solutions tests adjustable concrete screws for levelling of elements against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): installation and functioning tests and characteristic resistance under tension and shear. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.

    What the EAD assesses

    EAD 330011-00-0601 covers adjustable concrete screws: self-tapping screws whose lower thread cuts into a pre-drilled hole in concrete while an upper thread or head geometry lets the fixed element be raised or lowered after installation, so that battens, sleepers, frames and similar elements can be levelled over an uneven base. The product is a concrete screw in its anchorage but a levelling device in its function, and the EAD reflects both. It assesses the characteristic resistance to tension and to shear, the behaviour of the screw when it bridges the adjustment gap between element and concrete, the installation parameters (drill diameter, hole depth, setting tool, torque) and durability. Only the use conditions and gap heights declared by the manufacturer and verified by test are covered.

    Assessment programme

    Screws are set in drilled holes in concrete members of the strengths to be claimed, using the manufacturer's installation tool, and the fixed element is positioned at the maximum adjustment height before loading. Reference tension and shear tests establish the resistance of the anchorage and of the shank, with the stand-off introducing bending into the shear series. Installation and functioning tests check that the screw sets with the specified drill bit at both ends of its tolerance, that the levelling thread still turns after setting, that repeated adjustment does not strip the concrete thread and that the screw holds under repeated loading. Series in cracked concrete, sustained load and corrosion protection are included where the manufacturer claims the corresponding use.

    What the report states

    The report gives the ultimate loads, failure modes (steel rupture, thread stripping, concrete cone, splitting) and displacements for each series, with mean and 5 % fractile, and the ratios of installation and functioning series to the reference tests. The TAB derives characteristic tension and shear resistances valid for the tested gap heights and concrete strengths, plus installation parameters, spacing and edge distances for the ETA.

    Where the result is required

    Adjustable concrete screws are used to level floor substructures, door and window frames, facade sub-frames and timber sleepers on concrete slabs, where shim-free height adjustment speeds up installation. The ETA under this EAD provides the data for verifying the fixing, normally with the design rules referenced in the ETA, and the product is CE marked under the AVCP system stated in the EAD. Screws intended for ordinary structural fixing without the adjustment function are assessed under EAD 330232 instead.

    What we assess

    • installation and functioning tests
    • characteristic resistance under tension and shear

    Products covered

    • adjustable concrete screws for levelling of elements

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    No. ETAs are issued by Technical Assessment Bodies designated under the CPR. Amstelfy carries out the assessment tests in its accredited laboratory, prepares the test reports to the EAD's clause structure and coordinates the test plan with the TAB of your choice.

    An ordinary concrete screw clamps the element against the concrete and is assessed as a structural fixing in cracked and uncracked concrete. An adjustable screw leaves a variable gap and carries load through its shank across that gap, so shear and bending at the maximum stand-off, the adjustment function and thread wear are tested as well. The two EADs lead to different ETAs.

    Yes. Shear resistance falls as the stand-off grows because the shank is loaded in bending, and the tension anchorage shortens if adjustment is made by turning the whole screw. The ETA therefore states the gap heights covered and the series are run at the least favourable height. Larger gaps than those tested cannot be claimed.

    The EAD works with a low-strength and a high-strength concrete that bracket the range to be claimed. If the product is only intended for standard floor slabs, limiting the claim to one class reduces the programme; a claim over the full range needs both ends. Lightweight or aerated concrete would need a separate assessment.

    Related standards