European Assessment Document

    EAD 330232-00-0601 - Mechanical fasteners for use in concrete

    Testing · NAC-037-TLCertification · NAC-026-PPSETA route

    In short

    EAD 330232-00-0601 is the EOTA European Assessment Document for mechanical fasteners for use in concrete. Amstelfy Technical Solutions tests torque-controlled expansion anchors, undercut anchors and deformation-controlled anchors against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): characteristic resistance in cracked and uncracked concrete, functioning tests (installation safety, crack cycling, repeated loads), tension, shear and combined loads and durability and sustained load. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.

    What the EAD assesses

    EAD 330232-00-0601 sets out how a post-installed mechanical fastener is assessed for a European Technical Assessment. It covers torque-controlled expansion anchors, displacement-controlled anchors, undercut anchors and concrete screws, used singly or in groups, in cracked or uncracked normal-weight concrete under static or quasi-static loading. The essential characteristics are the characteristic resistances to tension and shear for each failure mode (steel, pull-out, concrete cone, splitting, pry-out), the displacements under service load, the minimum spacing, edge distance and member thickness, and durability. The assessment is built from two families of test: reference tests that establish the resistance in low- and high-strength concrete, and functioning tests that show the fastener tolerates site conditions. Seismic performance categories C1 and C2 and fire resistance are optional extensions. The fastening itself is then designed with EN 1992-4 using the ETA values.

    Assessment programme

    Production fasteners are installed by the laboratory in unreinforced concrete slabs of controlled strength, in hammer-drilled holes at the specified drill-bit tolerance. Reference tension tests are confined or unconfined as the EAD prescribes; shear tests are made towards the free edge and away from it. Functioning tests cover installation safety (reduced torque, oversized holes, contact with reinforcement), crack-width cycling in a slab with controlled cracks at the width stated in the EAD, repeated loads and sustained load, and for expansion anchors the maximum torque test. For C1 or C2 the seismic series of EOTA TR 049 is added. The manufacturer chooses the concrete strength range, the use conditions and the load directions to be covered.

    What the report states

    The report gives, per fastener size and test series, the load-displacement curves, the failure mode, the mean and the 5 % fractile of the ultimate load, the scatter, and the reduction factor derived from each functioning series relative to the reference series. From these the Technical Assessment Body derives NRk and VRk, the displacement values, the installation parameters and the seismic data for the ETA annexes.

    Where the result is required

    The ETA based on this EAD is the input for anchor design to EN 1992-4 and for CE marking of the fastener under AVCP system 1. The same test members and procedures underlie the related assessments of bonded fasteners, fasteners for redundant non-structural systems and seismic qualification. Typical products are wedge anchors, sleeve anchors, drop-in anchors, undercut anchors and concrete screws for structural fixings in buildings, bridges and industrial plant.

    What we assess

    • characteristic resistance in cracked and uncracked concrete
    • functioning tests (installation safety, crack cycling, repeated loads)
    • tension, shear and combined loads
    • durability and sustained load
    • seismic performance categories C1 and C2 (Annex)

    Products covered

    • torque-controlled expansion anchors
    • undercut anchors
    • deformation-controlled anchors
    • concrete screws

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    No. ETAs are issued by Technical Assessment Bodies designated under the CPR. Amstelfy carries out the assessment tests in its accredited laboratory, prepares the test reports to the EAD's clause structure and coordinates the test plan with the TAB of your choice.

    The EAD defines the test series per size and per concrete condition. The smallest, a middle and the largest diameter usually run the full programme, while intermediate sizes are covered by reduced series. A complete range with seismic options means several hundred installations, so the matrix is agreed with the Technical Assessment Body before the slabs are cast.

    C1 covers pulsating tension and alternating shear in cracked concrete and is sufficient for lower seismicity and lower-importance structures. C2 adds reference tests at wider crack widths, cycling of the crack while the fastener is under load and stricter displacement limits, so it is required for higher seismicity. The series follow EOTA TR 049 and the values go into the ETA.

    No. Each failure mode is evaluated with its own criterion; pull-through gives a characteristic pull-out resistance and splitting gives a critical edge distance rather than a rejection. What ends a series is failure of a functioning criterion, for example excessive displacement during crack cycling, which usually points to the expansion mechanism rather than to the steel.

    Related standards