European Assessment Document
EAD 330232-00-0601 - Mechanical fasteners for use in concrete
In short
EAD 330232-00-0601 is the EOTA European Assessment Document for mechanical fasteners for use in concrete. Amstelfy Technical Solutions tests torque-controlled expansion anchors, undercut anchors and deformation-controlled anchors against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): characteristic resistance in cracked and uncracked concrete, functioning tests (installation safety, crack cycling, repeated loads), tension, shear and combined loads and durability and sustained load. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.
What the EAD assesses
EAD 330232-00-0601 sets out how a post-installed mechanical fastener is assessed for a European Technical Assessment. It covers torque-controlled expansion anchors, displacement-controlled anchors, undercut anchors and concrete screws, used singly or in groups, in cracked or uncracked normal-weight concrete under static or quasi-static loading. The essential characteristics are the characteristic resistances to tension and shear for each failure mode (steel, pull-out, concrete cone, splitting, pry-out), the displacements under service load, the minimum spacing, edge distance and member thickness, and durability. The assessment is built from two families of test: reference tests that establish the resistance in low- and high-strength concrete, and functioning tests that show the fastener tolerates site conditions. Seismic performance categories C1 and C2 and fire resistance are optional extensions. The fastening itself is then designed with EN 1992-4 using the ETA values.
Assessment programme
Production fasteners are installed by the laboratory in unreinforced concrete slabs of controlled strength, in hammer-drilled holes at the specified drill-bit tolerance. Reference tension tests are confined or unconfined as the EAD prescribes; shear tests are made towards the free edge and away from it. Functioning tests cover installation safety (reduced torque, oversized holes, contact with reinforcement), crack-width cycling in a slab with controlled cracks at the width stated in the EAD, repeated loads and sustained load, and for expansion anchors the maximum torque test. For C1 or C2 the seismic series of EOTA TR 049 is added. The manufacturer chooses the concrete strength range, the use conditions and the load directions to be covered.
What the report states
The report gives, per fastener size and test series, the load-displacement curves, the failure mode, the mean and the 5 % fractile of the ultimate load, the scatter, and the reduction factor derived from each functioning series relative to the reference series. From these the Technical Assessment Body derives NRk and VRk, the displacement values, the installation parameters and the seismic data for the ETA annexes.
Where the result is required
The ETA based on this EAD is the input for anchor design to EN 1992-4 and for CE marking of the fastener under AVCP system 1. The same test members and procedures underlie the related assessments of bonded fasteners, fasteners for redundant non-structural systems and seismic qualification. Typical products are wedge anchors, sleeve anchors, drop-in anchors, undercut anchors and concrete screws for structural fixings in buildings, bridges and industrial plant.
What we assess
- characteristic resistance in cracked and uncracked concrete
- functioning tests (installation safety, crack cycling, repeated loads)
- tension, shear and combined loads
- durability and sustained load
- seismic performance categories C1 and C2 (Annex)
Products covered
- torque-controlled expansion anchors
- undercut anchors
- deformation-controlled anchors
- concrete screws
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | Yes |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EAD 330499-00-0601 - Bonded fasteners for use in concrete
- EAD 330087-01-0601 - Systems for post-installed rebar connections with mortar
- EAD 330008-04-0601 - Anchor channels
- EAD 330011-00-0601 - Adjustable concrete screws
- EAD 330076-00-0604 - Metal injection anchors for use in masonry
- EAD 330083-02-0601 - Power-actuated fasteners for multiple use in concrete for non-structural applications
- EAD 330084-00-0601 - Steel plate with cast-in anchors
- EAD 330196-00-0604 - Plastic anchors for fixing of external thermal insulation composite systems with rendering