European Assessment Document

    EAD 330008-04-0601 - Anchor channels

    Testing · NAC-037-TLCertification · NAC-026-PPSETA route

    In short

    EAD 330008-04-0601 is the EOTA European Assessment Document for anchor channels. Amstelfy Technical Solutions tests cast-in anchor channels with channel bolts and serrated and non-serrated channels against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): tension and shear resistance of channel, anchor and bolt, flexural resistance of the channel lip, fatigue (where claimed) and seismic performance. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.

    What the EAD assesses

    EAD 330008-04-0601 assesses cast-in anchor channels: a hot-rolled or cold-formed steel profile with welded or forged anchors, embedded flush with the concrete surface, into which hammer-head or hook-head channel bolts are inserted after striking. Loads pass through the bolt, the channel lips, the profile and the anchors into the concrete, so each steel element has its own characteristic resistance: the anchor, the anchor-channel connection, local flexure of the lips, the channel bolt and bending of the profile between anchors, in tension and in shear perpendicular to the channel. Serrated channels with matching bolts add resistance to shear along the channel axis. Concrete failure modes (cone, pull-out of the anchor head, blow-out, edge failure, pry-out) are covered by calculation factors confirmed by test. Fatigue, seismic performance and durability are assessed where the manufacturer claims them.

    Assessment programme

    Channels are cast into unreinforced test members with anchors at the production spacing, and bolts are installed with the specified torque. Tension series load a bolt directly over an anchor to fail the anchor or its connection, and midway between anchors to fail the lips in local flexure; further series load the bolt alone. Perpendicular shear is applied through a fixture that lets the lips or the bolt govern, and longitudinal shear is applied along serrated channels while slip is recorded. Tests in low-strength concrete and in cracked members confirm the concrete-related factors. For seismic categories the EAD annex adds cyclic tension and shear with crack cycling; fatigue claims require cyclic series on the relevant steel elements.

    What the report states

    The report tabulates, per profile and bolt size, the ultimate loads, displacements and failure modes, the 5 % fractiles and the derived characteristic steel resistances of anchor, connection, lips and bolt, the flexural resistance of the channel, and for serrated channels the longitudinal shear resistance with its slip. The TAB enters these values and the concrete factors into the ETA annexes for design with EN 1992-4.

    Where the result is required

    Anchor channels are designed with EN 1992-4 and the supplementary EOTA rules for longitudinal shear, using the characteristic values of the ETA, and are CE marked under AVCP system 1. They serve precast facades, curtain-wall brackets, elevator guide rails, tunnel services and rail infrastructure where fixings must remain adjustable along a line. The US counterpart is ICC-ES AC232. Testing is accredited for version 04 of the EAD and product certification refers to version 02.

    What we assess

    • tension and shear resistance of channel, anchor and bolt
    • flexural resistance of the channel lip
    • fatigue (where claimed)
    • seismic performance

    Products covered

    • cast-in anchor channels with channel bolts
    • serrated and non-serrated channels

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Other versions on the scope: EAD 330008-02-0601

    Route to market

    Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    No. ETAs are issued by Technical Assessment Bodies designated under the CPR. Amstelfy carries out the assessment tests in its accredited laboratory, prepares the test reports to the EAD's clause structure and coordinates the test plan with the TAB of your choice.

    Because the concrete-related modes are calculated with EN 1992-4 from embedment depth, anchor spacing and head size, using factors that the EAD confirms with a limited number of tests in low-strength and cracked concrete. The steel path through anchor, connection, lips, bolt and profile cannot be calculated reliably for every geometry, so each element is tested to failure.

    A serrated channel transfers shear along its axis through the interlock between toothed lips and a matching bolt, so an additional series applies longitudinal shear while slip is measured, and the ETA gives a characteristic longitudinal shear resistance with the corresponding displacement. Non-serrated channels can only be designed for tension and shear perpendicular to the channel.

    The ETA is valid only for the bolt types, diameters and property classes that were tested in the channel, because lips and bolt head interact. Each claimed bolt is tested in tension and shear, and seismic or fatigue claims are repeated for every bolt and channel combination covered. Bolts from other sources are not covered by the ETA.

    Related standards