US qualification standard

    ACI 355.4 - Qualification of post-installed adhesive anchors in concrete

    Testing · NAC-037-TL

    In short

    ACI 355.4 - Qualification of post-installed adhesive anchors in concrete. Amstelfy's laboratory in Amstelveen performs this US qualification protocol for adhesive anchors for US qualification: bond strength in cracked/uncracked concrete, installation sensitivity and sustained load, freeze-thaw, temperature. Testing is on the ISO/IEC 17025 accreditation scope NAC-037-TL, which lets European manufacturers prepare US evaluation-report programmes without shipping samples overseas.

    What ACI 355.4 determines

    ACI 355.4 is the qualification standard for post-installed adhesive anchors, threaded rods or reinforcing bars bonded with an injection or capsule adhesive, that ACI 318 Chapter 17 requires before its bond-strength design provisions may be used. Where ACI 355.2 characterises a mechanical interlock, ACI 355.4 characterises a bond that is sensitive to how the hole was prepared, how wet it was, how the adhesive cured and how warm the concrete becomes in service. The standard therefore determines the characteristic bond stress in uncracked and cracked concrete, runs reliability tests for hole cleaning, moisture, installation direction and crack cycling, and adds sustained-load, freeze-thaw, elevated-temperature and chemical-resistance series. The anchor is placed in a category that sets the strength-reduction factor, and the adhesive is assigned temperature categories defined by a long-term and a short-term service temperature.

    Specimens, conditioning and procedure

    The complete system is installed in low- and high-strength test members following the printed instructions. Reference tension tests are confined so that bond rather than concrete breakout governs, in uncracked members and in cracked members at the crack width of the test table. Reliability series install anchors with reduced cleaning, in water-saturated and water-filled holes, horizontally and overhead, and apply crack-width cycling to installed anchors. Sustained-load tests hold a fraction of the reference load at standard and at the maximum long-term temperature while displacement is logged. Further series test bond at the short-term temperature, after freeze-thaw cycling and after exposure of adhesive specimens to alkaline and sulphurous environments; seismic simulation is cyclic tension and shear in cracked concrete.

    What the report states

    For each series the report gives bond stresses at failure, displacements, failure modes (adhesive-to-steel, adhesive-to-concrete, cone, steel), mean and 5 % fractile and the ratio to the reference. The qualification yields characteristic bond strengths for cracked and uncracked concrete per temperature category and installation condition, the anchor category, the sustained-load and temperature reductions, critical edge distance, seismic values and the installation parameters for the evaluation report.

    Where the result is required

    ACI 355.4 qualification supports adhesive anchor design under ACI 318 Chapter 17 and the International Building Code, and it is the technical basis of ICC-ES AC308, which adds requirements for an ESR, including a development-length route for post-installed reinforcing bars. Products are epoxy, vinylester, hybrid and cementitious adhesives for rods and rebar in US and other ACI-based markets. The European counterparts are EAD 330499 for anchors and EAD 330087 for rebar connections.

    What we assess

    • bond strength in cracked/uncracked concrete
    • installation sensitivity
    • sustained load, freeze-thaw, temperature

    Products covered

    • adhesive anchors for US qualification

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    US and international evaluation-report programmes (ICC-ES, IAPMO UES, ACI 318 qualification) accept data from ISO/IEC 17025-accredited laboratories. Amstelfy runs these programmes in the Netherlands so European manufacturers avoid shipping samples overseas; the evaluation report itself is issued by the evaluation service.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Adhesive injected overhead or horizontally can run out of the hole or trap air before it gels, leaving voids that reduce bond. ACI 355.4 therefore requires series installed in those directions when the manufacturer wants them covered, and the evaluation report lists the permitted orientations. Sustained tension in overhead installations is also subject to specific design and installer requirements in ACI 318.

    Each category pairs a long-term temperature, at which sustained-load tests are run and which represents the concrete temperature over the life of the anchor, with a short-term temperature for brief peaks such as sun exposure. Bond strength is tested at both, and the evaluation report gives bond values per category, so the designer picks the category matching the service conditions.

    The standard prescribes a minimum duration and the displacement is recorded throughout; the creep curve is then extrapolated to the design life and compared with the displacement at which adhesion was lost in the reference tests. Series at the long-term temperature and at standard temperature run in parallel, and this part usually determines the length of the programme.

    Related standards

    All Anchors, fasteners & post-installed rebar testing