US qualification standard

    ACI 355.2 - Qualification of post-installed mechanical anchors in concrete

    Testing · NAC-037-TL

    In short

    ACI 355.2 - Qualification of post-installed mechanical anchors in concrete. Amstelfy's laboratory in Amstelveen performs this US qualification protocol for mechanical anchors for US (ACI 318 / IBC) qualification: reliability and service-condition tests, cracked concrete and seismic simulation and reference tension and shear tests. Testing is on the ISO/IEC 17025 accreditation scope NAC-037-TL, which lets European manufacturers prepare US evaluation-report programmes without shipping samples overseas.

    What ACI 355.2 determines

    ACI 355.2 is the American Concrete Institute qualification standard for post-installed mechanical anchors, the reference that ACI 318 Chapter 17 requires before an expansion, undercut or screw anchor may be designed with its provisions. The standard establishes suitability through three groups of tests. Reference tests in uncracked and cracked concrete of low and high strength provide the pull-out and concrete-breakout parameters. Reliability tests check sensitivity to installation faults, to crack-width cycling and to repeated loading. Service-condition tests establish minimum spacing and edge distance, the behaviour in cracked concrete and, for seismic use, simulated seismic tension and shear. The outcome of the reliability tests places the anchor in Category 1, 2 or 3, which sets the strength-reduction factor φ used in design. Qualification for cracked concrete and for seismic use is optional and is stated in the resulting evaluation report.

    Specimens, conditioning and procedure

    Anchors are installed in unreinforced test members of specified strength following the manufacturer's printed installation instructions, which become part of the qualification. Static tension and shear tests follow ASTM E488 with confined or unconfined set-ups as the test table requires, and cracked-concrete tests are run in members with hairline cracks opened to the width given in the table. Reliability series include installation with reduced torque or setting energy, oversized holes, crack-width cycling under constant load and repeated tension loading. Service-condition series include tests at reduced edge distance and spacing to find the critical values for splitting, tests at minimum member thickness and the seismic simulation under cyclic tension and shear in cracked concrete.

    What the report states

    The report tabulates per diameter the mean and 5 % fractile loads, coefficients of variation, failure modes and the normalised ratios between reliability and reference series, then states the anchor category and the design parameters: pull-out strengths in cracked and uncracked concrete, effectiveness factors for concrete breakout, the critical edge distance for splitting, seismic strengths and installation torque. These feed the design-information table of an ICC-ES evaluation report.

    Where the result is required

    ACI 355.2 qualification is the basis for anchor design under ACI 318 Chapter 17 and the International Building Code, and it is the technical core of ICC-ES AC193, which adds supplementary requirements for an ESR. It applies to wedge, sleeve, drop-in, undercut and screw anchors from any manufacturer selling into US and other ACI-based markets. The European equivalent is the assessment under EAD 330232; the test members and much of the instrumentation are the same.

    What we assess

    • reliability and service-condition tests
    • cracked concrete and seismic simulation
    • reference tension and shear tests

    Products covered

    • mechanical anchors for US (ACI 318 / IBC) qualification

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    US and international evaluation-report programmes (ICC-ES, IAPMO UES, ACI 318 qualification) accept data from ISO/IEC 17025-accredited laboratories. Amstelfy runs these programmes in the Netherlands so European manufacturers avoid shipping samples overseas; the evaluation report itself is issued by the evaluation service.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    The reliability tests compare the capacity of the anchor under adverse installation and crack conditions with its reference capacity. The smaller the loss and the scatter, the better the category: Category 1 anchors are the least sensitive and receive the highest strength-reduction factor φ in ACI 318, Category 3 the lowest. The category is stated per diameter in the evaluation report.

    It is an optional part. Anchors intended for structures in Seismic Design Categories C to F must pass the simulated seismic tension and shear tests, run as cyclic loading in cracked concrete, in addition to the cracked-concrete qualification. Anchors qualified only for uncracked concrete cannot be used where cracking or seismic loading is expected.

    The physics are the same and many series overlap, so a manufacturer with an ETA under EAD 330232 already has slabs, installation data and reference results that help in planning. The programmes differ in crack widths, loading protocols, statistical evaluation and reporting, so series are normally run separately for each route rather than converted.

    Related standards

    All Anchors, fasteners & post-installed rebar testing