US qualification standard

    ICC-ES AC308 - Acceptance criteria for post-installed adhesive anchors in concrete elements

    Testing · NAC-037-TL

    In short

    ICC-ES AC308 - Acceptance criteria for post-installed adhesive anchors in concrete elements. Amstelfy's laboratory in Amstelveen performs this US qualification protocol for adhesive anchors: test methods referenced in Tables 3.1 to 3.7. Testing is on the ISO/IEC 17025 accreditation scope NAC-037-TL, which lets European manufacturers prepare US evaluation-report programmes without shipping samples overseas.

    What ICC-ES AC308 determines

    ICC-ES AC308 governs the evaluation of post-installed adhesive anchors for an ICC-ES evaluation report under the International Building Code. It is built on ACI 355.4 and on ASTM E488 and E1512, and its Tables 3.1 to 3.7 assemble the test programme according to the anchor element (threaded rod, reinforcing bar), the installation conditions claimed (dry, water-saturated or water-filled holes, hammer-drilled or diamond-cored holes, horizontal and overhead installation) and the optional claims (cracked concrete, seismic, sustained tension). AC308 adds to ACI 355.4 the provisions needed for the ESR: design information in the format of ACI 318 Chapter 17 with bond strengths per temperature category, requirements for installer training and inspection where the code demands them, and a development-length design method for post-installed reinforcing bars.

    Specimens, conditioning and procedure

    The laboratory follows the tables for the claims made. Reference confined tension tests in low- and high-strength uncracked concrete and in cracked concrete give the baseline bond stress; reliability series install anchors with reduced cleaning, in saturated and water-filled holes, in diamond-cored holes where claimed and in horizontal and overhead orientation, and subject installed anchors to crack-width cycling. Sustained-load tests run at standard and at the long-term temperature of each temperature category; bond is also tested at the short-term temperature, after freeze-thaw and after alkaline and sulphurous exposure. Seismic qualification adds cyclic tension and shear in cracked concrete. For rebar development-length claims the tables add series on reinforcing bars at the embedments the design method requires.

    What the report states

    The report follows the AC308 tables with bond stresses, displacements, failure modes, mean, coefficient of variation, 5 % fractile and the ratio of each series to its reference. The ESR converts them into characteristic bond strengths for cracked and uncracked concrete per temperature category and installation condition, the anchor category and strength-reduction factors, sustained-load and seismic reductions, and the installation table with drilling methods, cleaning steps and curing times.

    Where the result is required

    An AC308 ESR is required for adhesive anchors and post-installed rebar on US projects under the IBC and ACI 318, and is requested in Middle East, Asian and Latin American markets that follow US codes. Manufacturers with an ETA under EAD 330499 or EAD 330087 generally run AC308 as a parallel programme on the same adhesive. The ESR also governs field requirements such as installer certification for overhead sustained-tension applications.

    What we assess

    • test methods referenced in Tables 3.1 to 3.7

    Products covered

    • adhesive anchors

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    US and international evaluation-report programmes (ICC-ES, IAPMO UES, ACI 318 qualification) accept data from ISO/IEC 17025-accredited laboratories. Amstelfy runs these programmes in the Netherlands so European manufacturers avoid shipping samples overseas; the evaluation report itself is issued by the evaluation service.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    ACI 355.4 is the qualification standard: it defines the tests, the evaluation and the categories. AC308 is the ICC-ES document that applies it for an evaluation report, assembling the programme in its tables, adding conditions such as diamond-cored holes, overhead installation and rebar development-length design, and prescribing how the ESR presents the data. Laboratories test to ACI 355.4 and the ASTM methods; ICC-ES issues the ESR against AC308.

    AC308 allows a reinforcing bar bonded with the adhesive to be designed either as an anchor with the bond-strength provisions of ACI 318 Chapter 17 or, with additional tests, by the development-length provisions of ACI 318 as if it were cast in. The second route needs its own series on bars at the relevant embedments and is listed separately in the ESR.

    Each claimed condition adds series: diamond-cored holes, water-filled holes, overhead installation and sustained tension in those orientations are all separate. Claiming everything gives the broadest ESR but the longest programme; many manufacturers start with hammer-drilled holes in dry and saturated concrete and add conditions later as a revision. The decision should be made before the slabs are planned.

    Related standards

    All Anchors, fasteners & post-installed rebar testing