Test method
EN 13948 – Root penetration test
Flexible sheets for waterproofing - resistance to root penetration
In short
EN 13948 - Flexible sheets for waterproofing - resistance to root penetration. Amstelfy's laboratory determines resistance to root penetration of roof waterproofing sheets according to EN 13948 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.
What EN 13948 determines
EN 13948 determines the resistance of roof waterproofing sheets to penetration by plant roots, which decides whether a membrane may be used under a green roof without a separate root barrier. The test is biological rather than mechanical: planting boxes are lined with the membrane, including seams made as on site, filled with growing substrate and planted with a vigorous, aggressively rooting woody species, and cultivated under controlled conditions for a growth period of two years. Roots press into every weakness, so the test exposes thin spots, seam defects and degradable components that a mechanical test would miss. At the end the membrane and seams are dismantled and inspected; any root that has grown through or into a seam is a failure. The method is derived from the FLL procedure used in Germany.
Specimens, conditioning and procedure
The manufacturer supplies the sheet and makes, or specifies, the seams and details to be included, since seams are the usual point of failure. Several boxes are lined with the membrane with seams in the base and at the corners, and reference boxes without membrane confirm that the plants are vigorous. Boxes are filled with substrate, planted with the prescribed species at the prescribed density and kept in a greenhouse under controlled temperature, light, irrigation and fertilisation for two years, with the plant growth recorded. At the end the substrate and roots are removed, the membrane is examined on both faces and the seams are opened to check for roots that have entered or passed through.
What the report states
The report states, for each box, whether roots penetrated the membrane or grew into a seam, with photographs of the dismantled specimens, the condition of the plants in the test and control boxes and the growing conditions over the period. The product is reported as resistant to root penetration only if no penetration occurred in any box. The manufacturer declares the result where the product standard provides for it and uses it to permit green-roof application.
Where the result is required
Cited by EN 13707 for bitumen roofing sheets and EN 13956 for plastic and rubber roofing sheets as the optional characteristic for sheets intended under green roofs, and required by green-roof guidelines and public specifications that demand a root-resistant membrane. Also used for membranes under planters, roof gardens and podium landscaping. Liquid-applied kits assessed under EAD 030350-00-0402 can be tested in the same way where root resistance is claimed.
What we assess
- resistance to root penetration
Products covered
- roof waterproofing sheets
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | No |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EAD 030350-00-0402 - Liquid applied roof waterproofing kits
- EAD 220069-00-0402 - Flat and profiled plastic roofing sheets made of recycled material for fully supported discontinuous roofing
- EAD 030218-01-0402 - Membranes for roof or wall underlays or both
- EN 13859-1 - Flexible sheets for waterproofing - underlays for discontinuous roofing
- EN 13859-2 - Flexible sheets for waterproofing - underlays for walls
- EN 13967 - Flexible sheets for waterproofing - plastic and rubber damp proof sheets including basement tanking
- EN 13969 - Flexible sheets for waterproofing - bitumen damp proof sheets including basement tanking
- EN 15814 - Polymer modified bituminous thick coatings for waterproofing - definitions and requirements