Test method

    EN ISO 12236 – Geosynthetic CBR puncture test

    Geosynthetics - static puncture test (CBR test)

    Testing · NAC-037-TL

    In short

    EN ISO 12236 - Geosynthetics - static puncture test (CBR test). Amstelfy's laboratory determines CBR puncture resistance of geotextiles, geogrids and geocomposites according to EN ISO 12236 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN ISO 12236 determines

    EN ISO 12236 quantifies the resistance of a geosynthetic to a slowly applied, localised load. A circular specimen is clamped between two rings with an internal diameter of 150 mm, and a flat-ended steel plunger of 50 mm diameter is driven through it at constant speed until the specimen ruptures. The maximum force reached is the push-through force; the plunger travel at that force is reported with it. The geometry is borrowed from the California Bearing Ratio soil test, and it loads the product in all directions at once, a useful single-number index for separation and protection geotextiles stressed by angular fill. Because the result depends on the fixed clamp and plunger dimensions, it ranks products and detects production changes but gives no design stress, and it is not applicable to geogrids with apertures large relative to the plunger.

    Specimens, conditioning and procedure

    At least five specimens, cut to EN ISO 9862 from positions across the sample and conditioned where needed, are clamped in turn so that the material is flat and free of slack without being pre-tensioned; the clamping force has to prevent slippage through the rings, which is checked on the first specimen. The plunger is advanced at 50 mm per minute by a testing machine with a calibrated force transducer, and force against displacement is recorded until the force drops after rupture. Products that do not rupture within the available travel are reported as such. Wet testing is an option. Geocomposites are tested as the complete product unless the client asks for individual layers.

    What the report states

    The report lists the push-through force in N or kN and the displacement at maximum force in mm for each specimen, with the mean and coefficient of variation, and notes any slippage, partial puncture or non-rupture. The mean is declared, with its tolerance, as the static puncture (CBR) characteristic in the Declaration of Performance, and manufacturers use it as a routine FPC parameter because it is quick and sensitive to changes in mass and bonding.

    Where the result is required

    Static puncture resistance is a required characteristic in the harmonised geotextile standards EN 13249 to EN 13257 and EN 13265, including EN 13252 for drainage systems, EN 13253 for erosion control and EN 13254 for reservoirs and dams, and it appears in the geosynthetic barrier standards such as EN 13361. Specifications for separation layers under roads and railways, protection layers over geomembranes and filter wraps commonly set a minimum CBR force by robustness class.

    What we assess

    • CBR puncture resistance

    Products covered

    • geotextiles
    • geogrids
    • geocomposites

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    CBR is a static, slow push with a flat 50 mm plunger and gives a force; the cone drop of EN ISO 13433 is dynamic, with a pointed cone falling onto the specimen, and gives a hole diameter. The first represents sustained pressure from fill, the second the impact of a dropped stone during installation. Products rank differently in the two tests.

    The force depends on the 150 mm clamp and 50 mm plunger geometry, which fix the strain field in the specimen. A different plunger would give a different number. The test therefore classifies products and verifies consistency; design against puncture uses performance tests with the actual aggregate and pressure, or empirical survivability rules.

    Only when the apertures are small enough for the plunger to load a representative number of ribs. For geogrids with large openings the product standards accept that the test is not applicable and the characteristic is not declared; the laboratory records the aperture size against the plunger diameter in the report.

    Related standards

    All Geotextiles & geosynthetics testing