Test method

    EN 1110 - Flexible sheets for waterproofing - flow resistance at elevated temperature - bitumen sheets

    Testing · NAC-037-TL

    In short

    EN 1110 - Flexible sheets for waterproofing - flow resistance at elevated temperature - bitumen sheets. Amstelfy's laboratory determines flow resistance at elevated temperature of bitumen sheets according to EN 1110 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN 1110 determines

    EN 1110 determines the flow resistance of bitumen waterproofing sheets at elevated temperature, the counterpart of the cold-bend test at the other end of the temperature range. On a dark roof the surface can exceed 80 °C, and on a slope or an upstand a coating that softens flows downwards off its carrier. The method hangs specimens vertically in an oven at a controlled temperature for 2 h and measures how far the coating has moved relative to a reference mark; the sheet passes a temperature if the displacement does not exceed 2 mm. By repeating at increasing temperatures the highest temperature that satisfies this limit is found. The result reflects the softening behaviour of the bitumen compound and the grip of the carrier, and after heat ageing it shows how the compound hardens.

    Specimens, conditioning and procedure

    Specimens are cut from the sheet, with release films removed and the direction recorded. A reference mark is applied across the specimen and the position of the coating relative to the carrier or to a fixed point is measured. Each specimen is suspended vertically from a clamp in a ventilated oven preheated to the test temperature and left there for 2 h. After cooling, the displacement of the coating is measured, on each face where the two faces are coated differently. The sequence is repeated with new specimens at temperatures increasing in the steps the standard prescribes until the displacement exceeds 2 mm. Where only compliance with a declared value is needed, the test is run at that single temperature.

    What the report states

    The report gives the flow resistance temperature in °C, the highest temperature at which the displacement of the coating remained within 2 mm, or, for a single-temperature check, the measured displacement in mm at the declared temperature and a pass or fail. Both faces are reported where they differ. The value is declared in the Declaration of Performance and repeated after artificial ageing where the product standard requires.

    Where the result is required

    Cited by EN 13707 for bitumen roofing sheets, before and after ageing to EN 1296, and by EN 14695 for bridge-deck sheets, where hot asphalt is laid on the membrane. Also used for bitumen underlays and flashings exposed on sloped roofs and for self-adhesive sheets whose adhesive compound must not creep. In development it ranks APP, SBS and oxidised compounds and checks whether a filler change has reduced heat stability.

    What we assess

    • flow resistance at elevated temperature

    Products covered

    • bitumen sheets

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    The standard fixes a tolerable slippage, 2 mm in 2 h, and finds the temperature at which the sheet still meets it. This turns a gradual softening process into a single declarable temperature. The 2 mm limit is small enough that the coating stays on its carrier and the lap geometry is unchanged, which is what matters for the roof.

    Both expose a vertical bitumen specimen to heat and measure flow, but EN 1110 tests a factory-made sheet with a carrier and seeks the highest passing temperature in steps, whereas EN 15818 tests a cured liquid-applied coating on a plate at one fixed temperature from EN 15814 and reports pass or fail. The two results cannot be compared.

    Granules do not flow, but the bitumen under them does, and the mark must be placed so that it tracks the compound rather than the loose surfacing. Sheets are tested with their surfacing in place because that is how they are used; the underside, usually a thin film or sand, is tested as well, and the lower of the two temperatures is decisive.

    Related standards